Panasonic ER-VW Manual

Panasonic ER-VW Manual

Thin type ionizer
Hide thumbs Also See for ER-VW:

Advertisement

Quick Links

High-frequency AC Method
Thin Type Ionizer
ER-VW
* The contents of this catalog are as of October 2017.
2022.7
For the latest information, please visit our company website.

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic ER-VW

  • Page 1 High-frequency AC Method Thin Type Ionizer ER-VW * The contents of this catalog are as of October 2017. 2022.7 For the latest information, please visit our company website.
  • Page 2 The angles of the two nozzles can be adjusted within a range of approximately 190° by screwing down the ends of the nozzles. After adjusting the angle, turn the ends of the nozzles to tighten them and secure them at that angle. This allows the nozzle angles of the ER-VW to be adjusted easily after installation. Installation examples...
  • Page 3: Basic Performance

    Removing charges from LCD module clamps Removing charges during cell production BASIC PERFORMANCE Minimum air consumption 15 ℓ/min. (ANR) No damage to electronic devices from inverse charging ER-VW can utilize air A high-frequency 68,000 When object is Comparison of air consumption (–) charged...
  • Page 4: Order Guide

    The functions support accurate charge removal This function causes discharging to stop automatically if the In addition to the air supply monitoring function, the ER-VW supply of air drops below a certain pressure. Notification of is equipped with the following functions to ensure accurate this is given when the AIR indicator lights and the discharge charge removal.
  • Page 5: Specifications

    ER-VW Thin Type Ionizer SPECIFICATIONS Type Spot type ER-VW Item Model No. Applicable CE marking directives EMC Directive, RoHS Directive Charge removal time (±1,000 V → ±100 V) 1 sec. or less (Note 2) Ion balance ±10 V or less (Note 2) Ozone generation 0.05 ppm or less (Note 3)
  • Page 6 ER-VW Thin Type Ionizer I/O CIRCUIT AND WIRING DIAGRAMS I/O circuit diagram Symbols … D : Reverse supply polarity protection diode : Input protection diode : Surge absorption zener diode , Tr , Tr : NPN output transistor Joint connector (9-pin) (Set the end connector, if not joint.)
  • Page 7: Precautions For Proper Use

    ER-VW Thin Type Ionizer PRECAUTIONS FOR PROPER USE Adjusting the air blowing direction • This product is to remove static electricity • After screw down the nozzle to loosen it, point it toward for industrial use. Never use this product for the object to be charge removal.
  • Page 8: Maintenance

    ER-VW Thin Type Ionizer PRECAUTIONS FOR PROPER USE Maintenance • Make sure that the power supply is off while wiring and inspection. Otherwise, there is a danger of accident, electric shock or • Always be sure that the power supply and the malfunction.
  • Page 9 ER-VW Thin Type Ionizer DIMENSIONS (Unit: mm in) The CAD data can be downloaded from our website. ER-VW Ionizer main unit 0.217 5.000 Joint for ø6 mm ø0.236 in air tube Plug with 3.150 hexagonal hole 0.276 1.575 1.654 16.3 0.642...
  • Page 10 Disclaimer The applications described in the catalog are all intended for examples only. The purchase of our products described in the catalog shall not be  regarded as granting of a license to use our products in the described applications. We do NOT warrant that we have obtained some  intellectual properties, such as patent rights, with respect to such applications, or that the described applications may not infringe any  intellectual property rights, such as patent rights, of a third party. Panasonic Industry Co., Ltd. Industrial Device Business Division 7-1-1, Morofuku, Daito-shi, Osaka 574-0044, Japan industrial.panasonic.com/ac/e/ Specifications are subject to change without notice. ⓒ Panasonic Industry Co., Ltd. 2022.7   Printed in Japan...