Cisco OL-10426-01 User Manual page 85

Release 15.3.00
Table of Contents

Advertisement

Chapter 4
Configuration Tables and Fields
Table 4-22 FastPAD Configuration
Topic
Required Settings
Setting Switch
Model Settings table
Software Release
Make sure that the value of Switch Software Release is set to the release that
is to be modeled. If that value is one that defaults to FastPAD (817 to 824, or
840 to 849), NMT will design FastPADs for any non-voice feeder
connections. All other values default to MC3810 for non-voice feeder
connections.
Adding FastPAD
Data Traffic table
Data Connections
Type field: Enter the data traffic speed.
BC (Back Card) field: For each end of the connection, enter the back card of
the FTC/FTM card that links the hub IPX/IGX switch to the FastPAD (T1, E1,
V, or X).
Fdr BC (Feeder Back Card) field: Enter the connection interface on the line
side of the FastPAD (S, R, V, V1, or V6).
Adding FastPAD
Voice Traffic table
Dedicated Voice
Type field: Enter ATC8, ATC12, ATC16, CELP8, or CELP48. The numbers
Connections
refer to kbps.
BC (Back Card) field: For each end of the connection, enter the back card of
the FTC/FTM card that links the hub IPX/IGX switch to the FastPAD (T1, E1,
V, or X).
Fdr BC (Feeder Back Card) field: For each end of the connection, enter V for
the VFC-03 card.
Adding FastPAD
Bursty Traffic table
Bursty Data
Type field: Enter FR.
Connections
BC (Back Card) field: If the end has a FastPAD, enter the back card of the
FTC that links the hub IPX/IGX switch to the FastPAD (T1, E1, V, or X). If
the end is not a MC3810, enter the back card of the FRP/FRM at that end (also
T1, E1, V, or X).
Fdr BC (Feeder Back Card) field: If the end has a FastPAD, enter the
connection interface on the line side of the FastPAD (S, R, V, V1, or V6). If
the end does not have a FastPAD, leave this field blank.
OL-10426-01, Rev. A0
Comments
FastPADs will not be designed for
non-voice connections under the
default switch software release (920).
To force NMT to use FastPADs, the
Feeder Table must be used; see
Changing Default Parameters
FastPAD data connections must
originate and terminate on a FastPAD.
If the switch software release supports
the MC3810, NMT will design
MC3810s, not FastPADs, unless the
hub ID fields and the Feeder table are
used.
For each feeder back card entry, the
NMT establishes a dedicated virtual
circuit that connects one data port on
one FastPAD to one data port on
another FastPAD.
FastPAD dedicated voice connections
must originate and terminate on a
FastPAD.
For each back card field entry, the
NMT establishes a dedicated virtual
circuit that connects one voice card on
one FastPAD to one voice card on
another FastPAD.
A FastPAD bursty data connection
may have one end at a FastPAD and
the other at an IPX/IGX FRP/FRM
card. At least one end of the
connection must have an entry in the
Fdr BC.
Cisco WAN Modeling Tools Guide
FastPAD
below.
4-39

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wan modeling tools

Table of Contents