Troubleshooting Fx Port Connectivity
S e n d c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m .
Counter Values (5 minute averages):
Usually a port in this state cycles between the initializing state and the off-line state. If this the error,
verify that the switch port is configured as an F port. A port that is mistakenly set to be E port could
cause this error when connecting to an N port. If setting the switch port to autodetect mode still doesn't
resolve the issue, try to statically configure the port type in order to match the Nx port behavior with
respect to loop or point-to-point initialization. There are some limited case in which the port type auto
negotiation could not work properly for incompatibility with some old HBAs. (The automatic detection
for the port mode is not applicable on an OSM module where at maximum one TE/E port can be configured
per quad.)
If after having statically configured the port mode, it still doesn't come up, verify that the HBA is
working properly and possibly power-cycle the HBA (i.e. booting the server or resetting the adapter).
To check whether a FLOGI is issued to the switch during the Fx port initialization, the fcanalyzer can
be used.
In the example below, the fcanalyzer tool has been used with the necessary filtering to capture the FLOGI
sent by the N port. Refer to the Cisco MDS 9000 Family Configuartion Gude for more information.
Frame 25 (176 bytes on wire, 176 bytes captured)
Ethernet II
MDS Header(SOFi3/EOFt)
Fibre Channel
FC ELS
Cmd Code: FLOGI (0x04)
Common Svc Parameters
Class 1 Svc Parameters
Class 2 Svc Parameters
Class 3 Svc Parameters
Class 4 Svc Parameters
Cisco MDS 9000 Family Troubleshooting Guide
3-16
0 address id, 0 delimiter
0 EOF abort, 0 fragmented, 0 unknown class
3016111132 frames output, 6029792843852 bytes, 0 discards
Received 14 OLS, 14 LRR, 0 NOS, 31 loop inits
Transmitted 87 OLS, 23 LRR, 65 NOS, 37 loop inits
0 frames input, 41 bytes, 0 discards
0 runts, 0 jabber, 0 too long, 0 too short
0 input errors, 0 CRC, 0 invalid transmission words
0 address id, 0 delimiter
0 EOF abort, 0 fragmented, 0 unknown class
0 frames output, 112 bytes, 0 discards
Received 0 OLS, 0 LRR, 0 NOS, 0 loop inits
Transmitted 0 OLS, 0 LRR, 0 NOS, 0 loop inits
B2B Credit: 3
Common Svc Parameters: 0x0 (Normal B2B Credit Mgmt)
0000 .... = BB_SC Number: 0
.... 1000 0100 0000 = Receive Size: 2112
Max Concurrent Seq: 0
Relative Offset By Info Cat: 0
E_D_TOV: 0
N_Port Port_Name: 10:00:00:09:c9:28:c7:01 (00:09:c9)
Fabric/Node Name: 10:00:00:09:c9:28:c7:01 (00:09:c9)
Service Options: 0x0(Class Not Supported)
Service Options: 0x0(Class Not Supported)
Service Options: 0x8800(Seq Delivery Requested)
Initiator Control: 0x0(Seq Delivery Requested)
Recipient Control: 0x0(Seq Delivery Requested)
Class Recv Size: 0
Total Concurrent Seq: 0
End2End Credit: 0
Open Seq Per Exchg: 0
Chapter 3
Troubleshooting Switch Level Issues and Interswitch Connectivity