Panasonic LP-GS Series Operation Manual page 292

Laser marker navi smart
Hide thumbs Also See for LP-GS Series:
Table of Contents

Advertisement

26 Maintenance
2.
3.
4.
5.
292
The values represent the recommended values, if the damage threshold
(maximum average power density) of the detector is 1kW/cm
LP-RC350S: approx. 50mm
LP-RF200P: approx. 90mm
LP-RV200P: approx. 90mm
The values represent the recommended values, if the damage threshold
(maximum average power density) of the detector is 10kW/cm
(2)
(1)
(1) Work distance (base position)
(2) Installation distance for detector
(3) Laser head
(4) Detector of laser power meter
(5) Laser beam
(6) Workpiece
Do not install the detector at the work distance. This may cause destruction of the laser power meter.
LP-GS052: Do not use the pointer as a reference to determine the position of the detector. Since
the pointer is emitted diagonally, it does not indicate the center of the marking field at the specified
installation distance.
Establish an online connection between your PC and the laser marking system.
Go to the "Maintenance" screen and select the "Laser pumping" tool.
Select "Yes" to start laser pumping. After a few seconds, laser pumping is completed
and the status icon of the "Laser pumping" tool changes.
Select "Laser radiation for measurement".
In the dialog, enter the desired laser power and other laser settings.
The settings specified for the inspection of laser power are saved in the laser marking
system.
LP-RV: The laser power changes depending on the settings for pulse duration and
pulse cycle. If you select "Optimal setting", the software automatically sets the optimal
values for "Pulse duration [ns]" and "Pulse cycle [μs]".
(3)
(4)
(5)
(6)
2
.
2
.
ME-NAVIS2-OP-1