NOTICE
© Copyright 2015 ABB. All rights reserved.
Taking out of operation
Shutting down the turbocharger
Fitting the cover plate
Close the opening in the turbine casing using the cover plate (A).
Fasten the cover plate on the turbine casing (51000) using the
fastening strips (51002), Verbus Ripp® Verbusripp washers (51003)
and nuts (51007) and screw it down securely on the support.
Thoroughly clean the fastening strips (51002) before fitting them. Apply
high-temperature grease to the stud threads (51006).
Operation Manual / TPS48-D/E.. - TPS61-D/E..