FOR USE ONLY WITH LOW VOLTAGE LANDSCAPE LIGHTING POWER UNITS THAT ARE RATED
MAXIMUM 25 AMPS, 15 VOLTS PER CIRCUIT.
Do not install fixture within 10 feet (3.05 meters) of a pool, spa or fountain.
INSTALLATION INSTRUCTIONS
1. Make sure power is turned OFF before installing or servicing this fixture.
2. This fixture must be mounted to a junction box or mounting stake that is UL Listed for low voltage and wet
locations. Mounting stakes S1, S3, S4, S6, S7, S8 or boxes M0029, BI1, BI2 may be used.
3. Insert the fixture wire throught the 1/2" NPS hole in the stake cap (or junciton box lid) and screw the fixture in to the
cap/lid.
4. Attach the stake cap to the stake (or lid to the junciton box) taking care not to pinch the wire.
5. Loosen the relamping screw, remove the roof and globe and set aside.
6. Install specified lamp (included).
7. Clean the gasket area if required and replace the roof and globe. Tighten the relamping screw.
8. Wire fixture following instructions below for low voltage connector.
9. Turn power ON.
LOW VOLTAGE CABLE CONNECTOR INSTRUCTIONS
Low voltage cable connector to be used with 10 or 12 gauge supply cable and 18 gauge fixture cable. Philips
recommends using SPT-3 water resistant (marked "WA", "W" or similar marking) supply cable such as our SCW500-
10/BSCW500-10 or our SCW100-12/BSCW100-12. Philips also recommends ordering the entire system, which includes the
power console (maximum 25 Amps, 15 Volts per circuit), fixture(s) (low voltage cable connector included) and supply
cable to ensure proper installation and operation.
When using our supply cable, it can be laid on top of the ground, placed under "ground cover" (that is, shallow burial less
than 6 inches or 15.2 cm deep), or directly buried in accordance with the NEC. If not using our cable, per UL 1838-Standard
for Low Voltage Landscape Lighting Systems, the secondary cable must be SPT-3 or suitable for wet locations, sunlight
resistant and direct burial per UL 493 and sized per UL 1838, and it must be buried less than 6 inches (15.2 cm).
Philips recommends a minimum depth of 4 inches when burying in the lawn to prevent damage from aerators or other lawn
plugging equipment.
The 18 gauge fixture cable (provided with fixture) must be protected by routing in close proximity to the fixture or secured
to a building structure such as a house or deck. The fixture cable must be cut off so that it is connected to the low voltage
cable connector within 6 inches (15.2 cm) of the fixture or the building structure. When making an underground connection
to the 10 or 12 gauge supply cable (not provided), the fixture cable must not be buried more than 6 inches (15.2 cm).
WARNING-Mount the luminaire in or on non-combustible mounting surfaces only.
WARNING-Risk of Electric Shock. Install all luminaires 10 feet (3.05m) or more from a pool, spa, or fountain.
1.
Connect the supply cable to the terminals on the power console (transformer) and turn ON.
2.
Disassemble the connector by removing the Phillips head screw.
3.
Inspect the connector to ensure the prongs are straight. If the prongs are bent, straighten with pliers.
4.
Insert the end of the fixture cable into the square opening in the connector body. Bend wire over so that wire is laying in
the recess marked '18 GA'. This will help hold the wire in place while performing steps 5 and 6. Only 2-wire cable is to be
used and the common (smooth) wire and hot (ribbed) wires must be oriented as shown.
5.
Press the supply cable into the recess marked '10,12/2 GA' on the connector body. Again the common (smooth) wires
and the hot (ribbed) wires must be oriented as shown.
6.
Press the connector cover onto the connector body, making sure the screw holes line up with each other.
7.
Assemble the connector by tightening the Phillips head screw. NOTE: Make sure the metal prongs in the connector
pierce all 4 wires; the fixture will light as the prongs pierce the wires.
cover
fixture cable
32001019, revision I
screw
supply cable
body
hot (ribbed)
common (smooth)
page 2 of 2