5
Mount optional accessories
[If no sensors are used, skip to Section 6.]
To install outdoor air sensor
M28491
To install indoor air sensor
To install Entry/Exit Remote or Vent Boost Remote
1 Mount the sensor on a vertical exterior
2 Place sensor securely in bracket, facing
1 Remove the wallplate and mount it 4
2 Attach sensor securely to wallplate as
M32936B
Mounting the remote is optional.
1 Remove the front cover from the
2 Use provided screws and wall anchors
3 Replace the cover on the remote.
M33095
11
CTK04 ComfortNet™ Communicating Thermostat
wall, at least 6 inches below any
overhang. Choose a location protected
from direct sunlight.
away from wall.
to 6 feet above the floor on an interior
wall. Drill 3/16-inch holes for drywall,
7/32-inch for plaster.
shown.
Do not install the indoor air sensor where it can be affected by:
•
Drafts or dead spots behind doors and in corners.
•
Hot or cold air from ducts.
•
Radiant heat from sun or appliances.
•
Concealed pipes and chimneys.
•
Unheated (uncooled) areas such as an outside wall
remote.
to fasten the remote to the wall. Drill
3/16-inch holes for drywall, 7/32-inch
for plaster.
I/O-CHTSTAT03 69-2688—11