Noise/Vibration Information; Explanation Of Figures; Installation - Honda Miimo HRM70 Live Owner's Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
8 | English

Noise/Vibration Information

Noise emission values determined according to
EN 50636-2-107 .
Typically the A-weighted noise levels of the product are:
Sound power level 61 dB(A). Uncertainty K = 2 dB .

Explanation of Figures

Action
Accessories
Delivery scope/unpacking the mower
Laying out perimeter wire
Extending perimeter wire
Laying perimeter wire around new
inner object
Lifting up and carrying the mower
Setting the height of cut
Place and Mow
Adding a further lawn area
– with additional docking station (right)
– without additional docking station
(top left)
Cleaning
Maintenance
Power supply unit connection

Installation

Check if the perimeter wire is fully pegged to
the ground avoiding any slack lengths of
wire . Any loose wire can be a trip hazard .
Remove stones, loose pieces of wood, wire, live mains
cables and other foreign objects from the cutting area.
Make sure that the cutting area is even and has no ditches,
grooves and steep slopes above 15°/27 % that are clear
obstructions for the mower.
The docking station must be positioned on the wire at an
outer edge of the cutting area. It may not be positioned
on the side of a tool or garden shed standing as an island
within the lawn to be mowed .
It is recommended that you mow your lawn once with a
conventional lawnmower before installing and before the
first mowing of the new season and whenever the grass
clippings would be longer than 5 mm .
The mower's cutting system is designed to cut small
lengths of grass (30–50 mm). The clippings can remain as
mulch to fertilize the lawn. The height of cut for mower
can be adjusted to 30, 40 and 50 mm.
It is recommended to start with a higher setting and then
gradually decrease the height of cut as the wire disappears
under the grass. This prevents your Miimo from cutting
the wire .
Additional perimeter wire can be added using a wire
connector (see figures D–E).
The perimeter wire can be extended up to a maximum
length of 350 m.
The perimeter wire can be buried up to 5 cm under the
ground (or under non-metallic slabs).
To avoid causing damage to the perimeter wire, do not
verticut or rake the area where it is positioned .
When laying out the wire avoid angles of less than 45°.
This can affect the performance.
Display
Figure Page
A
100
B
101
C
101
D
102
E
102
F
103
G
103
H
104
I
104
Symbol
J
105
K
105
L
106
The display switches into sleep mode, if no input is made
for 10 minutes.
Meaning
Back button
Confirm button
If the confirm button is pressed whilst
mowing, the mower will return to the
docking station
Red LED on: mower error
Green LED on: mower is switched on
Green LED off: The mower is inactive
and your four-digit PIN code is required
for activation.
Or the mower is shut off, the On/Off
switch must be turned on and your four
digit PIN code must be entered to activate
the mower .
Note: during a software update, the green
LED and red LED will be on .
Left/right button
Down/up button
Display with dialog screen
Garden number (shown when more than
1 2 3
one garden map in the mower memory)
Network signal present
Network signal absent

Advertisement

Table of Contents
loading

Table of Contents