Specifications; Table 2: (B)86431-0X Power Unit Specifications - GE T1 Multiplexer Installation Manual

Junglemux sonet multiplexer
Table of Contents

Advertisement

7. SPECIFICATIONS

Specifications for the (B)86431-0X and B86431-4X Power Units are provided in
the following table.
regardless of the option.
(B)86431-0X POWER UNIT SPECIFICATIONS
Type
Physical
Electrical
(B)86431-01
(24V Station Battery)
Electrical
(B)86431-02
(48V Station Battery)
Electrical
(B)86431-03
(130V Station Battery)
Environmental
Mechanical
EMI/RFI
Isolation
Reliability

Table 2: (B)86431-0X Power Unit Specifications

Copyright  GE Multilin Inc. 2001-2013
Unless otherwise specified, the values are the same
Parameter
Height
Width
Depth
Weight
Input Range
Current Drain at 12 W
Maximum Output
Fuse
Input Range
Current Drain at 12 W
Maximum Output
Fuse
Input Range
Current Drain at 12 W
Maximum Output
Fuse
Operating
Storage
Relative Humidity
Shipping Altitude
Vibration
Bench Handling
Meets ANSI/IEEE
Meets ANSI/IEEE
per TR-NWT-000332
342-86400-431PS
Issue 2.1
March 2013
Page 20
Specification
89 mm (3.5 in.)
29 mm (1.135 in.)
203 mm (8.0 in.)
360 g (13 oz)
21 - 28 VDC
625 mA
18 W
GMT, fast-acting, 2A
42 - 56 VDC
312 mA
18 W
GMT, fast-acting, 1A
115 - 143 VDC
115 mA
18 W
GMT, fast-acting, 0.5A
-20 to +60 C
(-4 to +140 ºF)
-40 to +70 C
(-40 to +158 ºF)
5 to 95 % @ 40 C
15,000 m (50,000 ft)
per MIL-STD 810E
per TS 1-00446.06
C37.90.2 RFI
C37.90.1 SWC
800,000 Hours

Advertisement

Table of Contents
loading

This manual is also suitable for:

T1mx86431

Table of Contents