Honeywell Eclipse WX0050 Operating Instructions Manual page 12

Winnox nozzle-mix, low-emissions air heating burner
Table of Contents

Advertisement

General
Turndown: 7:1 to 17:1.
Burner style:
WX0050–WX0600: upright or inverted, right or left hand piping,
WX0850: upright, right or left hand piping.
Fuel types:
WX0050: natural gas,
WX0100–WX0200: natural gas, propane,
WX0300–WX0850: natural gas, propane, butane.
High fire visible flame length: Flame is inside tube at all times.
Excess air at high fire: 40–70%
Piping connection: NPT or BSP threaded connections are availa-
ble.
Flame detection: flame rod or UV scanner.
temperatures
Maximum process temperature: 1800°F (982°C).
Recommended maximum chamber temperature:
Model
standard alloy tube
WX0100–
1300°F (704°C)
WX0600
WX0850
1300°F (704°C)
Tube temperatures should be reduced 150°F (65°C) when using
propane or butane.
Weight
All weights are approximate.
Burner with packaged blower:
Model
WX0050
WX0100
WX0200
WX0300
WX0400
WX0500
WX0600
WX0850
Burner without blower:
Model
WX0050
WX0100
WX0200
WX0300
WX0400
WX0500
WX0600
WX0850
Fuel type, HHV, WoBBe Index
Gross heating
Fuel
symbol
value (HHV)
Natural
CH
90%
1000 BTU/ft
4
Gas
+
(11,1 kWh/m
Propa-
2525 BTU/ft
C
H
3
8
ne
(28,11 kWh/m
3330 BTU/ft
Butane
C
H
4
10
(37,14 kWh/m
BTU/ft
3
at standard conditions (kWh/m
High temperature
alloy tube
1550°F (843°C)
1400°F (760°C)
Weight
lbs (kg)
146 (66)
192 (87)
262 (119)
351 (159)
347 (158)
505 (229)
456 (207)
1435 (651)
Weight
lbs (kg)
107 (49)
124 (56)
180 (82)
228 (104)
224 (102)
338 (153)
289 (131)
1135 (515)
speci-
WoBBe
fic
Index
gravity
3
0.60
1290 BTU/ft
3
3
)
3
1.55
2028 BTU/ft
3
3
)
3
2.09
2303 BTU/ft
3
3
)
3
at normal conditions)
EN-12
secondary by-pass fuel setting
Tap B
Tap D
Tap C
Measuring taps
WX0050:
Fuel
Flame detection
Natural gas
UV scanner
Natural gas
Flame rod
WX0100–WX0850:
Model
natural gas
WX0100
4.0 (10.0)
WX0200
4.0 (10.0)
WX0300
4.5 (11.3)
WX0400
8.0 (20.0)
WX0500
8.0 (20.0)
WX0600
8.0 (20.0)
WX0850
4.0 (10.0)
1) Measured between Tap "E" and the chamber at low fire.
note: Input at low fire changes with ratio regulator adjustment.
Tap E
Tap C
Δp
"w.c. (mbar)
1)
0.5 (1.2)
1.5 (3.7)
Propane
Butane
Δp "w.c. (mbar)
1)
1.0 (2.5)
1.5 (3.8)
2.5 (6.3)
8.5 (21.6)
3.5 (8.9)
2.0 (5.1)
2.0 (5.1)
8.0 (20.0)
8.0 (20.0)
4.0 (10.0)
4.0 (10.0)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents