Download Print this page

Sealey LP35 Instructions page 3

Propane heaters

Advertisement

fig 4.
F
WARNING! if the flame shuts down during operation, before repeating the ignition operations make sure the fan is not jammed, and the air
p
inlet and outlets are completely free of obstructions. If the flame shuts off during normal operation due to overheating the cause of the problem
must be determined and corrected before repeating the ignition procedure.
5. COOL AIR FAN
The Propane Space Heater may also be used as a cool air fan, to do so:
5.1.
Remove the gas supply hose and plug the heater into the mains electrical power supply.
5.2.
Switch fan position “I” on. The unit will now blow out cool air only.
6.
MAINTENANCE
F
WARNING! Before commencing service or maintenance disconnect the unit from the electrical power, and the gas supply. Use authorised
p
parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
6.1.
Check the gas supply hose condition, and change if necessary.
6.2.
Check the starting electrode to ensure the gap is 5mm (fig 8).
6.3.
Check the ignition unit, safety thermostat, and thermocouple condition
and ensure they are clean.
I
Caution: Wear safety goggles to perform this operation.
s
6.4.
Clean inside the heater unit and the fan blade with compressed air.
7. TROUBLESHOOTING
PROBLEM
The fan motor
does not work
The ignitor does
not spark
No gas flow
to the burner
The burner starts, but it
stops as the gas valve
is released.
The heater stops
during operation
Declaration of Conformity
Propane Heaters Models:
LP35, LP60, LP80, LP100, LP125, LP200, & LP300.
73.23/EEC Low Voltage Directive.
89/336/EEC EMC Directive.
Gas Appliances (Safety) Regulations 1992
NOTE:
It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this equipment
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: Call us for a copy of our latest catalogue and promotions on 01284 757525. Leave your full name and address including your postcode.
s
fig 5.
POSSIBLE CAUSE
1.
There is no electrical supply
2.
The motor has locked.
1.
Electrode has the wrong gap.
2.
Faulty connection
1.
The cylinder gas tap is closed
2.
The cylinder is empty
3.
Gas leaks from the supply.
1.
The thermocouple is not
warm enough
2.
The safety override has
activated because the fan
does not work.
1.
Excessive gas supply
2.
Insufficient gas supply line.
3.
Insufficient air flow due to
formation on the cylinder.
We, the sole importer into the UK, declare that the products listed here are in conformity with the following EEC standards and directives
The construction files for these products are held by the Manufacturer and may be inspected
by a national authority upon request to Jack Sealey Ltd
Signed by Mark Sweetman
Sealey Group,
Bury St. Edmunds,
Suffolk.
fig 6.
fig 7.
fig.8.
5mm
SOLUTION
1.
Check mains power supply, wire, plug, and fuse.
2.
Unlock the motor with appropriate tool.
1.
Check and reset the electrode to the correct position (fig 7).
2.
Check and connect correctly the ignitor and the electrode.
1.
Open the gas tap
2.
Replace the cylinder
3.
Remove and clean the nozzle, check leaks by using a foamy
soap only. Stop the leak accordingly.
(DO NOT USE FLAME to find leak).
1.
Repeat the starting operation keeping the button
pushed for a longer time
2.
See above “Motor does not work”
1.
Check the pressure reducer, and replace if necessary.
2.
Check that the motor is working correctly.
3.
Check and if necessary use a larger gas cylinder, or
multiple cylinders connected parallel.
6th June 2000
01284 757500
E-mail: sales@sealey.co.uk
LP35, LP45, LP60, LP80X, LP100, LP145, LP200, & LP300. - 3 -300402
For Jack Sealey Ltd.
Sole importer into the UK
of Sealey Power Products
01284 703534

Advertisement

loading

This manual is also suitable for:

Lp45Lp60Lp80xLp100Lp145Lp200 ... Show all