14. Disassembly, disposal

14.1 Safety instructions for disassembly

Danger
Unintentionally switching on the compact booster unit
Danger to life!
The compact booster unit has to be voltage free during disas-
sembly. Turning off the system with the motor protection switch
does not securely shut off the motor inlet lines.
Only perform maintenance work on the compact booster unit if
you are sure that the compact booster unit is free of power.
Secure the compact booster unit against being switched on
unintentionally.
Danger
Danger of injury from electric voltage.
High shock currents and burns from direct and indirect contact with
live parts.
Turn off the power supply before disassembling the compact
booster unit and secure it from being turned on.
Warning
Components and lines under pressure
Personal and property damage!
Before work is done on pressure-retaining components, the
pump has to be depressurised!
Disconnect the pump from the power supply!
Warning
Inappropriate lifting/moving of heavy modules or components
Personal and property damage!
When moving heavy modules or components, use suitable
transport devices, lifting devices and lifting accessories.
Warning

15. Spare parts

Ordering text
1
Pump Movitec V 0609 B
Pump Movitec V 1008 B
Pump Movitec VF1506 B
Pump Movitec VF 2504 B
Pump Movitec VF 2505 B
Pump Movitec VF 4004-2 B
2
Pressure sensor
3
Pressure gauge
4
Float switch
5
Check valve 1 1/4"
Check valve
Check valve
Check valve
6
Shut-off valve 1 1/4"
Shut-off valve 1 1/2"
Shut-off valve
Shut-off valve
Shut-off valve
7
Frequency inverter - Pump drive 2.2 kW
Frequency inverter - Pump drive 3 kW
Frequency inverter - Pump drive 5.5 kW
Frequency inverter - Pump drive 7.5 kW
Frequency inverter - Pump drive 11 kW
Frequency inverter - Pump drive 15 kW
Honeywell GmbH
GB
Danger through improper disassembly
It is imperative to observe the laws and regulations on waste disposal
of materials that are detrimental to the environment.
B
Such materials include old oils, coolants, paint, plastics and chemicals.
If in doubt, consult the manufacturer.
1. Disassembly of the system.
- Collect grease and lubricants during disassembly.
2. Separate the pump materials for example according to:
- Metal
- Plastic
- Electronic junk
- Grease and lubricants
3. Dispose according to local regualtions or have them disposed of accor-
ding to regulations.
Nominal size CBU
OS.-No.
DN32
0904149
DN40
0904150
DN50
0904151
DN65A
0904152
DN65B
0904153
DN80
0904154
all
0904155
all
0904156
all
0904157
DN32 and DN40
0904158
DN50
0904159
DN65
0904160
DN80
0904161
DN32 and DN40
0904162
DN32 and DN40
0904163
DN50
0904164
DN65
0904165
DN80
0904166
DN32
0904167
DN40
0904168
DN50
0904169
DN65A
0904170
DN65B
0904171
DN80
0904172