Product Information; Product Description; Control Types; Important Notices On Usage - Bosch HPC 400 Installation Instructions For Contractors

User interface ems 2
Table of Contents

Advertisement

Product
information
3
Product information
3.1
Product description
• The user
interface is
used to control a heating system with a
maximum of four heating/cooling circuits and a cylinder primary
circuit for DHW heating, solar DHW heating and solar central heating
backup.
The user interface incorporates a time program:
- Heating
systems:
For each heating circuit, 2 time programs with
2 switching times per day. If a buffer cylinder is not installed,
heating circuits 2
...
4 can only switch to heating mode when
heating circuit 1 is in heating
mode.
- Domestic hot
water:
One time program for DHW heating and one
time program for the DHW circulation
pump,
each with 6
switching times per
day.
The user interface displays information about the heat source and
heating system and is used to change the settings.
After operating for 1'h
hour,
the user
interface
has a power reserve
of at least 8
hours.
If the power failure lasts longer than the power
reserve, the time and date will be deleted. All other settings are
saved.
• The functional scope and thus the menu structure of the user
interface are determined by the structure of the system. Your
attention
is
drawn to the importance of the system structure in the
relevant
places.
The adjustment ranges and default settings may
differ from the information in these instructions.
Certain
menu
items are specific to certain countries and
are
only
displayed if the country in which the heat pump
is
installed has been
set accordingly on the user
interface.
3.1.1
Control types
The following main control types are available for the heating system:
Weather-compensated:
Automated control of the flow temperature
based on the outside
temperature.
Weather-compensated with the
influence
of the room
temperature:
Automated control of the flow temperature based on
the outside temperature and room temperature. Installation of a
remote control in the reference room is
required.
If cobling is active, a set constant temperature
is
maintained.
Observe the further information on the control types and settings that
affect how the system
is
controlled (7 Chapter 6.3, page 17)
.
3.2
Important notices on usage
&
WARNING:
Risk of scalding!
I
If
t~ermal
disinfection
ha.
s been activated to avoid
legion ella, the hot water
IS
heated once to in excess of
65
·C.
The factory setting for the hot water temperature
is
60
·C.
There is a risk of scalding at the draw-off points
if the temperature
is
set higher than
this.
~
Make sure that a mixing device is installed.
&
NOTICE:
Floor damage!
I
~
For underfloor heating systems, make sure that the
maximum temperature for the floor type
in
question
is not
exceeded.
~
If necessary, connect an additional temperature
switch at the voltage input of the respective pump or
to one of the external
inputs
of the heat
pump.
• Only products from the same distributor may be used within the BUS
systero·
BOSCH
3.3
Additional accessories
For precise
information
regarding suitable
accessories,
refer to the
catalogue.
Function modules and user
interfaces
of the
EMS 2
control
system:
User
interface
CR 10
as simple remote control
User
interface
CR
10
H
as simple remote control with option to
measure relative humidity (heating/cooling circuits)
MM
100:
Module for heating/cooling circuits with mixing valve
MP
100:
Module for a swimming pool with heating via the heat pump
MM
100:
Module for solar DHW heating
MS
200:
Module for extended solar
systems.
Applicability of these instructions to EMS 2-capable modules
These instructions also apply to the user
interface
when used in
conjunction with heating/cooling circuit module MM 100 (accessory)
.
Additional setting options may be found in some menus, if your heating
system is equipped with alternative modules
(e.g.
solar module MS
100.
accessory)
.
These setting options are explained in the technical
documentation of the
modules.
4