Download Print this page

Mitsubishi Electric FR-E700 Series Installation Manualline page 9

Hide thumbs Also See for FR-E700 Series:

Advertisement

Main circuit terminal specifications
3.2
Main circuit terminal specifications
3.2.1
Terminal arrangement of the main circuit terminal, power supply and the motor
wiring
Three-phase 400V class
FR-E740-016(SC) to 095(SC)
Jumper
N/- P/+
R/L1 S/L2 T/L3
PR
Power supply
FR-E740-230(SC), 300(SC)
N/-
P/+ PR R/L1 S/L2 T/L3
Jumper
(230: M4/300: M5)
Power supply
Single-phase 200V class
FR-E720S-008(SC) to 030(SC)
Screw size (M3.5)
-
L1
N
Screw size
(M3.5)
Power supply
NOTE
Make sure the power cables are connected to the R/L1, S/L2, T/L3. Never connect the power cable to the U, V, W of the
inverter. (Phase need not be matched.) Doing so will damage the inverter.
Connect the motor to U, V, W. Turning ON the forward rotation switch (signal) at this time rotates the motor
counterclockwise when viewed from the load shaft.
6
Screw size (M4)
IM
Screw size
(M4)
Motor
Screw size (230: M4/300: M5)
Screw size
IM
Motor
Jumper
+
PR
IM
Motor
FR-E740-120(SC), 170(SC)
Screw size (M4)
Jumper
R/L1 S/L2 T/L3
N/-
P/+ PR
Power supply
FR-E720S-050(SC) to 110(SC)
Jumper
-
+
Screw size (M4)
L1 N
PR
Power supply
Screw size
(M4)
IM
Motor
IM
Screw size
(M4)
Motor