12.6 Drain pump
The pump should be inspected regularly
and particularly if:
• the appliance does not empty and/or
spin;
• the appliance makes an unusual noise
during draining due to objects such as
safety pins, coins etc. blocking the
pump;
• a problem with water draining is de-
tected (see chapter "Troubleshoot-
ing" for more details).
3.
4.
5.
6.
3.
A
B
4.
Remove the top part of the liquid
additive compartment.
Clean all the parts with water.
Clean the dispenser recess with a
brush.
Put back the dispenser in the recess.
WARNING!
Before unscrewing the pump
cover, switch the appliance off
and remove the mains plug from
the socket.
Proceed as follows:
1.
Unplug the appliance.
2.
If it is necessary, wait until the water
has cooled down.
Place a container close to the pump
to collect any spillage.
Release the emergency emptying
hose (B), place it in the container
and remove its cap cover.