Panasonic CU-E12QD3EA Service Manual page 60

Hide thumbs Also See for CU-E12QD3EA:
Table of Contents

Advertisement

15.5.2
H12 (Indoor/Outdoor Capacity Rank Mismatched)
Malfunction Decision Conditions
During startup, error code appears when different types of indoor and outdoor units are interconnected.
Malfunction Caused
Wrong models interconnected.
Wrong indoor unit or outdoor unit PCBs mounted.
Indoor unit or outdoor unit PCBs defective.
Indoor-outdoor unit signal transmission error due to wrong wiring.
Indoor-outdoor unit signal transmission error due to breaking of wire 3 in the connection wires between the indoor
and outdoor units.
Troubleshooting
AMP Air Conditioning
60
www.ampair.co.uk | sales@ampair.co.uk