Item
(12) Iris AE adjustment
Measurement terminal:
S terminal luminance signal output
(75 Ω termination)
Address: "0002" AE_CVT
Measuring instrument:
Oscilloscope (horizontal sync)
Object:
Grey scale
Data variation width:
"0000" to "00FE"
(1) Set the unit to the normal operation mode (write the data "
"0000").
(2) Video output is observed with the oscilloscope in the grey scale standard record
state, the data of address "0002" is rewritten, and the luminance signal level is
adjusted white to 760 ± 10mVp-p, gray of the background 420 ± 10mVp-p.
41
Adjustment method
VL-AX1S/H/E/EW/EX
FF" to the address
100mV/div