Getting Started; Installing/Changing Batteries; Operation Time; Optional External Power Source - RIDGID SeekTech ST-510 Operator's Manual

10 watt pipe and cable line transmitter
Hide thumbs Also See for SeekTech ST-510:
Table of Contents

Advertisement

SeekTech ST-510 Line Transmitter

Getting Started

Installing/Changing Batteries

To install batteries into the ST-510 Line Transmitter,
turn the knob on the battery holder counter clockwise.
The battery carriage will pull out slightly. Pull straight
back on the knob to slide out. Insert the batteries as
shown on the inside decal.
Fit the carriage into the case and turn the knob
clockwise while lightly pushing in to close. The
battery carriage can be installed in either orientation.
Figure 4: Inserting Battery Holder
Note: When replacing batteries use 8 D cells that
are the same type. Do not mix Alkaline with NiCd
(NiCad or Nickel Cadmium) for example. Be sure to
replace with batteries where all of the cells have the
same amount of charge. Do not mix half-used
alkalines with brand new ones.
CAUTION
Always remove batteries before shipping the
unit.
CAUTION
Do not allow debris or moisture into battery
compartment. Debris or moisture may short
the battery contacts, leading to rapid discharge
of the batteries, which could result in
electrolyte leakage or risk of fire.

Operation Time

Typical operation time for the SeekTech line
transmitter, using alkaline cells, is about 12.5 hours
which varies depending on factors such as load and
current transmitted, and how much the backlight is
on. Select
the Battery Saver feature if extended
battery life is needed. Other factors that affect the
operation time will include chemistry of the battery.
(Many of the new high performance batteries, such
as the "Duracell ® ULTRA" do last 10%-20% longer
than conventional alkaline cells under high demand
applications). Operation at low temperatures will also
reduce battery life. Typical operating times will be
generally on the order of those shown here. Note
that Battery Saver mode limits output current to 100
mA.
Estimated Operating Times
Current
400 mA
200 mA
100 mA
50 mA
25 mA
Batteries can recover after being subjected to high
loads. If time is allowed, batteries may recover
enough to offer additional hours of operation.

Optional External Power Source

Use only a power supply approved to IEC 61010-1 or
IEC 60950. Output must be isolated, SELV and
Limited-Energy Circuit per IEC 61010-1 or LPS per
IEC 60950, 12-15VDC, 30W minimum. Output
connection is standard barrel plug, 2.1mm pin, tip
positive.
Est. Time to Depletion
1.8 hours
3.6 hours
7.25 hours
14 hours
28 hours

Advertisement