Fig. 18. Install the conduit on the cabinet and make wiring connections to contact tray.
Wiring W8600E
IMPORTANT
Run wires separately from any other current-
carrying wires.
All wiring must comply with local codes and ordinances.
Run 4-wire thermostat cable (up to 18 gauge), independent
of any other current-carrying wires, from the W8600E base
to the terminal strip on the power box of the F50E.
AIR CLEANER
CABINET (TOP)
SCREWS (2)
CONTACT
TRAY
1
QUICK
CONNECT
TERMINAL
1
SCREW
(1)
SPRING
CLIP
F50E DUCT MOUNTED ELECTRONIC AIR CLEANER
1
FLEXIBLE
CONDUIT
CONTAINING
THREE
SPECIAL
LEADWIRES
RATED
FOR
15KV.
1
WHITE
GROUND
LEADWIRE
CONTACT TRAY
1
PROVIDED WITH 136377A REMOTE MOUNT KIT.
Strip 1/4 in. of insulation from the ends of the wires and
connect them (1 to 1, 2 to 2, 3 to 3, 4 to 4) as shown in
Fig. 22.
Install the W8600E cover and visually check the
installation appearance as shown in Fig. 23.