Adjustment - Kenwood TK-8360 Service Manual

Hide thumbs Also See for TK-8360:
Table of Contents

Advertisement

Test Equipment Required for Alignment
Test Equipment
1.
Standard Signal Generator (SSG)
2.
Power Meter
3.
Deviation Meter
4.
Digital Volt Meter (DVM)
5.
Oscilloscope
6.
High Sensitivity
Frequency Counter
7.
Ammeter
8.
AF Volt Meter (AF VTVM)
9.
Audio Generator (AG)
10. Distortion Meter
11. 4Ω Dummy Load
12. Regulated Power Supply
13. Spectrum Analyzer
14. Tracking Generator
Test cable for microphone input (E30-3360-28)
GREEN
1
RED
2
BLACK
3
BLUE
4
SHIELD
5
WHITE
6
GRAY
7
YELLOW
8
MIC connector (Front panel view)
1 : MBL
2 : SB
8
3 : GND
4 : PTT
5 : ME
6 : MIC
1
7 : HOOK
8 : DM
TENTATIVE

ADJUSTMENT

Frequency Range
Modulation
Output
Input Impedance
Operation Frequency
Measurement Range
Frequency Range
Measuring Range
Input Impedance
Frequency Range
Frequency Stability
Frequency Range
Voltage Range
Frequency Range
Output
Capability
Input Level
Center Frequency
Output Voltage
1
2
E
3
PTT
4
MIC-E
5
MIC
6
HK
7
8
TK-8360/8360H/8360H
Major Specifi cations
400 to 520MHz
Frequency modulation and external modulation
–127dBm/0.1µV to greater than –7dBm/100mV
50Ω
400 to 520MHz or more
Vicinity of 100W
400 to 520MHz
1 to 20V DC
High input impedance for minimum circuit loading
DC through 30MHz
10Hz to 1000MHz
0.2ppm or less
20A or more
50Hz to 10kHz
1mV to 3V
20Hz to 20kHz or more
0 to 1V
3% or less at 1kHz
50mV to 10Vrms
Approx. 4Ω, 10W or more
13.6V, approx. 20A (adjustable from 9 to 17V)
Useful if ammeter equipped
50kHz to 600MHz
100mV or more
Tuning cable (E30-3383-05)
Adapter cable (E30-3383-05) is required for inject-
ing an audio if PC tuning is used.
See "PC Mode" section for the connection.
Lead wire +
Shield wire –
MIC
U
(
)
33

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tk-8360hTk-8360hu

Table of Contents