Activation Character
This sets the character used to trigger scanning when using Character Activation Mode. On the
(Code Page
1252), page A-3, find the hex value that represents the character you want to use to trigger scanning. Scan
the following bar code, then use the
character. Scan
Save
End Character Activation After Good Read
After a bar code is successfully detected and read from the scanner, the aimer can be programmed either to remain on and
scanning, or to turn off. When End Character Activation After Good Read is enabled, the aimer turns off and stops
scanning after a good read. If you scan Do Not End Character Activation After Good Read, the aimer remains on after
a good read. Default = End Character Activation After Good Read.
Do Not End Character Activation
After Good Read
Character Activation Timeout
You can set a timeout for the length of time the aimer remains on and attempting to decode bar codes when using Charac-
ter Activation Mode. Set the length (in milliseconds) for a timeout by scanning the following bar code, then setting the time-
out (from 1-65535 milliseconds) by scanning digits from the
Character Deactivation Mode
If you have sent a character from the host to trigger the scanner to begin scanning, you can also send a deactivation character
to stop scanning. Scan the following On bar code to use character deactivation, then use Deactivation Character (following) to
select the character you will send from the host to terminate scanning. Default = Off.
* Off
3 - 12
Programming Chart
to finish.
Activation Character
Character Activation Timeout
to read the alphanumeric combination that represents that ASCII
Programming
Chart, then scanning Save. Default = 5000 ms.
ASCII Conversion Chart
* End Character Activation After
Good Read
On