GP 2500A

2.11 To Start

2.11.1 Ensure that the generator is properly installed in an outdoor location.
2.11.2 Disconnect all loads from the generator.
2.11.3 Open the fuel valve (a1).
2.11.4 Turn the engine switch to "ON" (c1).
2.11.5 Pull the starter rope (d).
2.11.6 Open the choke as the engine warms (b1).
2.11.7 Allow the engine to warm up a few minutes before attaching loads.

2.12 To Stop

2.12.1 Turn off and disconnect all tools and appliances attached to the
2.12.2 Turn the engine switch to "OFF" (c2).
2.12.3 Close the fuel valve (a2).
See Sections Installation and Operator Safety while using Internal
Combustion Engines for installation warnings and safety guidelines.
Note: If the engine is cold, move the choke lever to the closed position
(b2). If the engine is hot, set the choke to the open position (b1).
Note: If the oil level in the engine is low, the red LED at the engine
switch will light and the engine will not start. If this happens, check the
oil level and add oil as needed.
generator.
Note: To stop the engine quickly in an emergency, turn the engine
switch to "OFF" (c2).