Download Print this page

Honeywell PB112C-GA Installation Manual page 2

Protection thermostat

Advertisement

Available languages

Available languages

PB112C-GA & PB112C-GB
4. If you wish to connect a remote control device, insert the
wires (use 18- to 22-gauge flexible wires) through one of
the two openings on the base and connect them to ter-
minals 2 and 3 (no polarity).
If your thermostat has the Vacation Mode, the mode can be
activated from an Aube telephone controller (CT240 or
CT241) or any other remote control device equipped with a
normally open (NO) dry contact. For more information on
this mode, see the thermostat's user guide.
5. Push the excess length of the high-voltage wires back
inside the electrical box.
6. Secure the power base to the electrical box using the
provided screws.
Installing the Control Module (faceplate)
1. Verify the settings of the configuration switches (if any)
on the back of the faceplate (see user guide).
2. Install the control module (faceplate) on the power base
(see user guide).
3. Apply power to the heating system. Verify the installa-
tion by making sure that the heating system can be
turned on and turned off by increasing and decreasing
the setpoint.
4. Test the ground fault protection.
Testing the Ground Fault Protection
To ensure the ground fault protection is always in working
order, test it once the thermostat is installed and on a monthly
basis thereafter.
TEST button/light
1. Increase the setpoint temperature above the measured
temperature in order to activate the heating system.
2. Press the TEST button.
• If the TEST light does NOT come on, the test has
failed. Cut power to the heating system at the main
electrical panel, have an electrician verify the
installation and, if necessary, replace the thermostat.
• If the TEST light comes on, continue the test.
Automation and Control Solutions
Honeywell International Inc.
1985 Douglas Drive North
Golden Valley, MN 55422
customer.honeywell.com
Floor
temperature
sensor
® U.S. Registered Trademark
© 2012 Honeywell International Inc.
69-2748EF—01
Printed in USA
3. Switch the thermostat to Standby then back to On.
• If the TEST light goes off, the test has passed. Set the
thermostat back to the desired temperature. The test
is now completed.
• If the TEST light remains on, the test has failed.
Continue with the rest of the procedure.
4. Switch the circuit breaker (at the service panel) of the
heating system to off then back to on.
5. Repeat the test. If the test fails again, cut power to the
heating system at the main electrical panel, have an
electrician verify the installation and, if necessary,
replace the thermostat.
Technical Specifications
Maximum Load
(resistive only)
Supply
Current
120 VAC, 50/60Hz 15 A
240 VAC, 50/60Hz 15 A
Model
Ground Fault Protection
GA
Ground Fault Circuit
Interrupter (GFCI), class A
GB
Equipment Ground Fault
Protection Device (EGFPD)
Heating cycle length: 15 minutes
Operating temperature: 0°C to 50°C (32°F to 122°F)
Storage temperature: -20 °C to 50 °C (-4 °F to 120 °F)
Size (H • W • D): 124 x 70 x 23 mm (4.89 x 2.76 x 0.91 in.)
Warranty
Honeywell warrants this product, excluding battery, to be free from defects in the workman-
ship or materials, under normal use and service, for a period of one (1) year from the date of
purchase by the consumer. If at any time during the warranty period the product is deter-
mined to be defective or malfunctions, Honeywell shall repair or replace it (at Honeywell's
option).
If the product is defective,
(i) return it, with a bill of sale or other dated proof of purchase, to the place from which
you purchased it, or
(ii) contact Honeywell. Honeywell will make the determination whether the product should
be returned, or whether a replacement product can be sent to you.
This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it
is shown by Honeywell that the defect or malfunction was caused by damage which occurred
while the product was in the possession of a consumer.
Honeywell's sole responsibility shall be to repair or replace the product within the terms
stated above. HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF
ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING,
DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR
IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some provinces, states or
regions do not allow the exclusion or limitation of incidental or consequential damages, so
this limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS
PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WAR-
RANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS
HEREBY LIMITED TO THE ONE-YEAR DURATION OF THIS WARRANTY. Some provinces,
states or regions do not allow limitations on how long an implied warranty lasts, so the above
limitation may not apply to you.
This warranty gives you specific legal rights, and you may have other rights which vary from
one province, state or region to another.
If you have any questions about the product, contact us at:
705 Montrichard Avenue
Saint-Jean-sur-Richelieu, Quebec
J2X 5K8
Canada
Tel: 1-800-831-2823
E-mail: aube.service@honeywell.com
L.L. Rev. 05-12
Power
Wiring
1800 W 4 wires, double pole
3600 W 4 wires, double pole
Current Leakage Limit
5 mA
15 mA

Advertisement

loading

This manual is also suitable for:

Pb112c-gb