24-HOUR ENROLLMENT DELETION AND DEFAULT
If the device is enrolled in a panel different than the intended panel, and you are unable to
delete it from the unintended panel, reset default the device to factory default setting:
1.
Open the cover and verify device is powered on.
2.
Press and hold the tamper switch for 20 seconds.
The Green enrollment LED rapidly flashes and the SiXREPEATER defaults.
3.
This procedure is available for 24 hours after enrollment with a panel and the device
remains powered (battery installed).
SENSOR LOCATION FEATURE
To verify the location of each SiX device in an installation, enter programming mode and
select a SiX device zone. The device LED (located on the PCB) lights (can take up to 30
seconds). NOTE: This LED is not seen with the cover on. To view, the tamper switch
must be pressed down on the SiXREPEATER. Select it again to turn the LED off or
select the next device to locate.
SUPERVISION
If module supervision is desired, assign the SiXREPEATER to a zone. This sends check-
in, low battery, AC loss, and RF jam messages. When prompted, toggle the tamper
switch to enroll the MAC ID number. The yellow LED should blink on when messages are
sent.
Program the zone configuration as follows:
Zone Type
Input Type
8 (24-hour aux)
3 (supervised RF)
NOTES:
The SiXREPEATER reports AC loss and RF jam conditions as "low battery"
status, which is also displayed on the control's keypads. This prevents either
condition from causing an alarm when the control is armed.
The SiXREPEATER will not repeat a message that has already been
repeated.
If an actual low battery condition is reported, it takes up to 12 hours after AC
power is restored for the low battery restore message to be sent (requires 12
hours for fully recharged battery).
TAMPER/LOW BATTERY REPORTING
The SiXREPEATER reports this condition to the control. If a low battery or tamper
condition exists all zones used on the module shows a trouble on the control.
IMPORTANT:
The first battery test occurs 1-hour after power up. To quickly verify a good
backup battery, unplug and then plug back in the power supply; the system will
perform a battery test within 1-minute.
LED INDICATIONS /
LED INDICATIONS
RSSI
Green /
Reliable Signal /
Green
Reliable Signal
Yellow /
Marginal Signal /
Yellow
Marginal Signal
Red /
No Signal /
Red
No Signal
Approval Listings / Approbations Homologations:
FCC / IC - ETL Listed to UL268 & 521
cETL Listed to ULC S530 & S531
Other Standards / Autres normes: RoHS
FEDERAL COMMUNICATIONS COMMISSION (FCC) & ISED
The user shall not make any changes or modifications to the equipment unless authorized by the Installation
Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to operate the
equipment.
FCC / ISED STATEMENT
This device complies with Part 15 of the FCC Rules, and ISED's license-exempt RSSs. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any
interference received, including interference that may cause undesired operation.
Cet appareil est conforme à la partie 15 des règles de la FCC et exempt de licence RSS d'ISED. Son
fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne doit pas causer d'interférences
nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les interférences causant une
réception indésirable.
Responsible Party / Issuer of Supplier's Declaration
of Conformity: Honeywell International, 2 Corporate
Center Drive., Melville, NY 11747, Ph: 516-577-2000
SPECIFICATIONS / SPÉCIFICATIONS:
B
Voltage /
Voltage
Transformer Part # /
Transformer Part #
Input Voltage /
Input Voltage
............................................ 100 ~ 240VAC, 50 ~60 Hz
Operating Voltage /
Operating Voltage
Maximum Transformer Distance /
Maximum Transformer Distance
....................................... 9.8ft. (3m)
Battery/ Pile ...................................................................... P/N 300-10342
Environmental
/Environmental
Operating Temperature /
Operating Temperature
.................................................... 14
NOTE: Charging the lithium battery stops when temperature is below 32
NOTE: Charging the lithium battery stops when temperature is below 32
Relative Humidity /
Relative Humidity
......................................................................................... max. sans condensation
Physical /
Physical
Dimensions /
Dimensions
................................................. Length /
Conduit Insert /
Conduit Insert
.......................................... 1/2 in (12.7mm)
Acceptable Cable Size /
Acceptable Cable Size
See Honeywell Installation Guide P/N 800-
24399– https://mywebtech.honeywell.com/.
Ê800-24400ZŠ
800-24400 5/18 Rev A
Loop
1
Power
RF Jamming
AC Powered /
OK, No Jamming /
AC Powered
OK, No Jamming
Operating on Battery /
Jam Detected /
Operating on Battery
Jam Detected
Low Battery /
Can't Avoid Jamming /
Low Battery
Can't Avoid Jamming
Partie responsable / Émetteur de la déclaration de
conformité du fournisseur : Honeywell
International, 2 Corporate Center Drive., Melville,
NY 11747, Tél. 516 577-2000
........................... 300-10259
............................. 5VDC (1A)
F (-10
C) to 140
............................... 95%, Non-condensing / 95%
Length
6.9 in (175 mm) x
Width / Width4.4 in (113 mm) x
Depth /
Depth
1.2 in (31 mm)
............... 14 – 22AWG
Voir les instructions d'installation complètes 800-
24399- https://mywebtech.honeywell.com/.
24-HOUR ENROLLMENT DELETION AND DEFAULT
If the device is enrolled in a panel different than the intended panel, and you are unable
to delete it from the unintended panel, reset default the device to factory default setting:
1.
Open the cover and verify device is powered on.
2.
Press and hold the tamper switch for 20 seconds
The Green enrollment LED rapidly flashes and the SiXREPEATER defaults.
3.
This procedure is available for 24 hours after enrollment with a panel and the device
remains powered (battery installed).
SENSOR LOCATION FEATURE
To verify the location of each SiX device in an installation, enter programming mode and
select a SiX device zone. The device LED (located on the PCB) lights (can take up to 30
seconds). NOTE: This LED is not seen with the cover on. To view, the tamper switch
must be pressed down on the SiXREPEATER. Select it again to turn the LED off or
select the next device to locate.
SUPERVISION
If module supervision is desired, assign the SiXREPEATER to a zone. This sends
check-in, low battery, AC loss, and RF jam messages. When prompted, toggle the
tamper switch to enroll the MAC ID number. The yellow LED should blink on when
messages are sent.
Program the zone configuration as follows:
Zone Type
8 (24-hour aux)
NOTES:
The SiXREPEATER reports AC loss and RF jam conditions as "low battery"
status, which is also displayed on the control's keypads. This prevents
either condition from causing an alarm when the control is armed.
The SiXREPEATER will not repeat a message that has already been
repeated.
If an actual low battery condition is reported, it takes up to 12 hours after
AC power is restored for the low battery restore message to be sent
(requires 12 hours for fully recharged battery).
TAMPER/LOW BATTERY REPORTING
The SiXREPEATER reports this condition to the control. If a low battery or tamper
condition exists all zones used on the module shows a trouble on the control.
IMPORTANT:
The first battery test occurs 1-hour after power up. To quickly verify a good
backup battery, unplug and then plug back in the power supply; the system will
perform a battery test within 1-minute.
BATTERY /
CAUTION!
The batteries used in this device may present a fire or chemical burn hazard if mistreated.
Do not recharge, disassemble, heat above 212°F (100°C) or dispose of in fire. Use
Panasonic CR123A or DURACELL DL123, DL 123A Lithium batteries. Use of other
batteries may present a risk of fire or explosion. Keep used batteries away from children.
Dispose of used batteries properly.
Remove old batteries. Wait 10 seconds and then replace with four new batteries. To avoid
a low battery indication when installing new batteries, both batteries must be installed
within 15 seconds of installing the first one. Any low battery condition that may have
occurred should clear when the back plate is installed.
MISE EN GARDE!
Les piles utilisées dans ce dispositif peuvent présenter des risques d'incendie ou de
brûlure chimique si elles sont mal traitées. Ne rechargez pas, ne désassemblez pas, ne
faites pas chauffer et ne jetez pas au feu les piles à plus de 100 °C (212 °F). Utilisez des
piles au lithium Panasonic CR123A ou DURACELL DL123, DL 123A. L'utilisation
d'autres types de piles peut présenter des risques de feu ou d'explosion. Gardez les
vieilles piles hors de la portée des enfants. Débarrassez-vous des batteries utilisées de
façon appropriée.
Retirez les vieilles piles. Attendez 10 secondes et remplacer-les par quatre nouvelles
piles. Pour éviter une indication de piles faibles lorsque vous installez de nouvelles piles,
les dos (2) piles doivent être installées en deçà de 15 secondes après l'installation de la
première. Toute condition de pilles faibles qui aurait pu se produire devrait être rétablie
une fois la plaque arrière installée.
REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH WHICH THIS
DEVICE IS USED, FOR DETAILS REGARDING LIMITATIONS OF THE ENTIRE ALARM
F (60
C)
SYSTEM.
F (0
C)
POUR LES LIMITES DU SYSTÈME D'ALARME AU COMPLET, REPORTEZ-VOUS AU
GUIDE D'INSTALLATION DU PANNEAU DE COMMANDE
F (0
C)
Support / Pour de l'assistance en ligne, visitez : https://mywebtech.honeywellhome.com/
U.S. warranty / U.S. garantie: www.honeywell.com/security/hsc/resources/wa
For patent info, see: / Pour des informations sur les brevets, voir :
www.honeywell.com/patents
MyWebTech
Input Type
3 (supervised RF)
BATTERY
Warranty
 2018 Honeywell International Inc. Honeywell and is a registered
trademark of Honeywell International Inc.
All other trademarks are the properties of their respective owners. All
rights reserved.
Loop
1
Patents

Advertisement

loading