FST-851A: FlashScan thermal detector 135°F (57°C). See
DN-6936.
FST-851RA: FlashScan thermal detector 135°F (57°C) with
rate-of-rise. See DN-6936.
FST-851HA: FlashScan 190°F (88°C) high-temperature ther-
mal detector. See DN-6936.
FAPT-851A: FlashScan Acclimate Plus low-profile multi-sen-
sor detector. See DN-6937.
FSL-751A: FlashScan VIEW laser photo detector. See DN-
6886.
DNR: InnovairFlex low-flow non-relay duct-detector housing
(order FSP-851A/FSP-851RA separately). Replaces FSD-
751PL/FSD-751RPL. See DN-60429.
DNRW: Same as above with NEMA-4 rating, watertight. See
DN-60429.
B224RBA: Low-profile relay base. See DN-60054.
B224BIA: Isolator base for low-profile detectors. See DN-
60054.
B210LPA: Low-profile base. Standard U.S. style. Replaces
B710LPA. See DN-60054.
B501A: European-style, 4" (10.16 cm) base. See DN-60054.
B200SA: Intelligent programmable sounder base, capable of
producing a variety of tone patterns including ANSI Temporal
3. Compatible with sychronization protocol. See DN-60054.
B200SCOA: Based on B200SA, with added CO detector
markings in English/French.
B200SRA: Sounder base, Temporal 3 or Continuous tone.
See DN-60054.
FMM-1A: FlashScan monitor module. See DN-6720.
FDM-1A: FlashScan dual monitor module. See DN-6720.
FZM-1A: FlashScan two-wire detector monitor module. See
DN-6720.
FMM-101A: FlashScan miniature monitor module. See DN-
6720.
FCM-1A: FlashScan control module. See DN-6724.
FCM-1-RELA: FlashScan releasing control module. See DN-
60390.
FRM-1A: FlashScan relay module. See DN-6724.
FDRM-1A: FlashScan dual monitor/dual relay module. See
DN-60709.
NBG-12LX: Manual pull station, addressable. See DN-6726.
N-MPS series: Manual pull stations, addressable and conven-
tional. For use in Canada only. See DN-5497.
FM-955: Addressable pull station with two FMM-101A mod-
ules.
FM-9551: Addressable pull station with one FMM-101A mod-
ule.
FM-955-20C: Addressable pull station with two open contacts.
FM-9551S20C: Addressable pull station with one open and
one closed extra contacts.
ISO-XA: Isolator module. See DN-2243.
XP6-CA: FlashScan six-circuit supervised control module.
See DN-6924.
XP6-MAA: FlashScan six-zone interface module; connects
intelligent alarm system to two-wire conventional detection
zone. See DN-6925.
XP6-RA: FlashScan six-relay (Form-C) control module. See
DN-6926.
XP10-MA: FlashScan ten-input monitor module. See DN-
6923.
SLC-IM: SLC integration module, for VESDAnet detectors.
See DN-60755\
N
O
ETWORKING
PTIONS
NCM-W, NCM-F: Standard Network Communications Mod-
ules. Wire and multi-mode fiber versions available. See DN-
6861.
HS-NCM-W/MF/SF/WMF/WSF/MFSF: High-speed Network
Communications Modules that can connect to two nodes.
Wire, single-mode fiber, multi-mode fiber, and media conver-
sion models are available. See DN-60454.
RPT-W, RPT-F, RPT-WF: Standard-network repeater board
with wire connection (RPT-W), multi-mode fiber connection
(RPT-F), or allowing a change in media type between wire and
fiber (RPT-WF). Not used with high-speed networks. See DN-
6971.
ONYXWorks: UL-listed graphics PC workstation, software,
and computer hardware. See DN-7048 for specific part num-
bers.
NFN-GW-EM-3: NFN Gateway, embedded. See DN-60499.
NWS-3: NOTI•FIRE•NET™ Web Server. See DN-6928.
CAP-GW: Common Alerting Protocol Gateway. See DN-
60576.
VESDA-HLI-GW: VESDAnet high-level interface gateway. See
DN-60753.
LEDSIGN-GW: UL-listed sign gateway. Interfaces with classic
and high-speed NOTI•FIRE•NET networks through the NFN
Gateway. See DN-60679.
OAX2-24V: UL-listed LED sign, used with LEDSIGN-GW. See
DN-60679.
E
, C
,
NCLOSURES
HASSIS
AND
CAB-BM Marine System: Protects equipment in shipboard
and waterfront applications. Also order BB-MB for systems
using 100 AH batteries. For a full list of required and optional
equipment, see DN-60688.
NFS-LBB: Battery Box (required for batteries over 26 AH).
NFS-LBBR: Same as above, but red.
BB-UZC: Backbox for housing the UZC-256. Required for
NFS-320 applications, black. For red, order BB-UZC-R.
SEISKIT-320/B26: Seismic mounting kit. Required for seismic-
certified applications with NFS-320C and BB-26. Includes bat-
tery bracket for two 26 AH batteries.
SEISKIT-LBB: Seismic kit for the NFS-LBB. Includes battery
bracket for two 55 AH batteries.
O
O
THER
PTIONS
411 Series: Slave Digital Alarm Communicator Transmitters.
See DN-6619.
IPGSM-4GC: Internet and Digital Cellular Fire Alarm Commu-
nicator. Provides selectable configurable paths: cellular only,
IP only, or IP primary with cellular backup. Connects to the pri-
mary and secondary ports of a DACT. See DH-60769.
NFS-320-RB: Replacement board with central processing unit
NOTE: Keypad must be removed before shipping old unit out
for repair.
NFS-320-RBC-FR: Replacement board with central process-
ing unit, Canadian French. NOTE: Keypad must be removed
before shipping old unit out for repair.
NOTE: For other options including compatibility with retrofit equip-
ment, refer to the panel's installation manual, the SLC manual (for
Canadian DN-60085:J • 12/20/2013 — Page 5 of 6
D
P
RESS
LATES

Advertisement

loading