Installation - Honeywell OnCell 3150A-LTE-EU Quick Start Manual

Industrial cellular router

Advertisement

▷ If the LED indicator on the OnCell G3150A-LTE's
LAN port lights up, it means a connection has
been established.
Step : Set up an IP address for the computer
4 Set an IP address on the same subnet as the
OnCell G3150A-LTE.
▷ Since the OnCell G3150A-LTE's default IP ad-
dress is 192.168.127.254, and the subnet mask
is 255.255.255.0, you should set the IP address
of the computer to 192.168.127.xxx and subnet
mask to 255.255.255.0.
Step 4: Use the web-based manager to
configure the OnCell G50A-LTE
5 Open your computer's web browser and type
http://192.168.127.254 in the address field to
access the homepage of the web-based man-
agement system.
▷ Before the homepage opens, you will need to
enter the username and password.
6 For first-time configuration, enter the default
username and password given below:
Username: admin
Password: moxa
7 Click on the Login button.
ATTENTION
For security reasons, we strongly recommend
changing the password. To change the password,
select Maintenance ➜ Username/Password, and
then follow the on-screen instructions.
▷ You must either click the Save Configuration or
the Restart button for the configuration changes
to take effect.

Installation

WARNING
– This equipment is intended to be used in a Re-
stricted Access Location, such as a dedicated
computer room, where access can only be gained
by SERVICE PERSONS or by USERS who have
been instructed about the fact that the metal
chassis of the equipment is extremely hot and
may cause burns.
– Service persons or users should pay special atten-
tion and take special precautions before handling
this equipment.
– Only authorized, well-trained professionals should
be allowed to access the restricted access loca-
tion. Access should be controlled by the authority
responsible for the location with lock and key or
a security identity system.
– External metal parts are hot!! Pay special at-
tention or use special protection before handling
this equipment.
ATTENTION
– The OnCell G3150A-LTE is NOT a portable mobile
device and should be located at least 20 cm away
from the human body.
– The OnCell G3150A-LTE is NOT designed for
the general public. A well-trained technician is
required to deploy the OnCell G3150A-LTE units
and safely establish a wireless network.
– For EXPLOSION-PROOF applications, the OnCell
G3150A-LTE is designed and certified to meet
ATEX and IECEx requirements. You should mount
the device in a suitable enclosure rated at least
IP54, in accordance with IEC/EN 60079-15 stand-
ard, so that it is accessible only by the use of a
tool. The device is not intended for use in an area
with pollution degree rating > 2 in accordance
with EN 60664-1.
– When you install the OnCell G3150A-LTE in an
enclosure, the antennas must also be installed
in such a way that they are inside the enclosure.
External antenna deployment is allowed only if
the antennas are certified for ATEX Zone 2 use
or confirm to IECEx standards.
DIN-Rail Mounting
▷ DIN-Rail Kit Dimensions:
Unit = mm (inch)
12.5 (0.49)
25.0 (0.98)
▷ The OnCell G3150A-LTE comes with a DIN-rail
kit attached to the back panel.
▷ Mount the OnCell G3150A-LTE on corrosion-free
mounting rails that meet the EN 60715 standard.
 Insert the upper lip of the DIN rail
hook of the DIN-rail mounting kit :
1
2
3
22.7
(0.89)
48.4
15.0
(1.91)
(0.59)
into the top
1
2