7�3�3 Installation
1� The protective cap is to be removed before installation. The sensor must be
handled with care to prevent damage to the front side.
2� Insert the speed sensor into the intended installation bore and make sure that
the O-ring is not damaged during insertion.
3� Completely press the speed sensor into the installation bore by hand until it is
firmly seated.
4� Fasten the speed sensor using the included or specified mounting bolt, required
tightening torque 8 Nm ±2 Nm (maximum tightening torque 10 Nm).
7�3�4 Notice on wiring and circuitry
• Lines from the sensor to the electronics must not be routed close to other
power-conducting lines in the machine.
• The wiring harness should be mechanically secured in the area in which the sensor
is installed (distance < 150 mm). The wiring harness should be secured so that
in-phase excitation with the sensor occurs (e.g. at the sensor mounting point).
• If possible, lines should be routed in the machine interior. If the lines are routed
outside of the machine, their secure mounting is to be ensured.
• Lines must not be kinked or twisted, must not rub against edges and must not be
routed through sharp-edged ducts without protection.