Robotics Trainings System WS502
EMERGENCY-STOP switches on the
Pneumatic pressure control
There are two protective doors on the front of the WS502 training system. These
are provided with EMERGENCY-STOP door switches, which safely shut down
doors
the system as soon as a door is opened.
There is a sliding door on the rear of the WS502 training system. It is provided
with EMERGENCY-STOP door switches which safely shut down the system as
soon as the sliding door is opened.
When operating the WS502 training system without a Bosch Rexroth expansion
module the sliding door must be closed.
If the WS502 training system is operated together with a Bosch Rexroth
expansion module, open the left sliding door (viewed from the rear) and mount
the expansion module to the rear of the WS502 training system. The existing
EMERGENCY-STOP door switch is then actuated by the mounted expansion
module.
The training system must only be operated with a maximum pneumatic operating
pressure of 5-6 bar. The pressure of the system is adjustable.
Guard
The WS502 training system is equipped with a guard (Makrolon panes) which
prevents contact of persons in the hazardous area of the system.
Danger due to missing or incomplete guards!
Risk of injury when operating the WS502 training system with missing or
incorrectly installed pane elements!
In case of missing or incorrectly installed pane elements, immediately take
the WS502 training system out of service!
Install the protective panes supplied with the WS502 training system
correctly.
Bosch Rexroth AG
WARNING
13/64
Safety information