System Description; General; Functions - Overview; System Design - Honeywell 023350.17 Mounting And Connection Instructions

Door controller module for mb
Table of Contents

Advertisement

Available languages

Available languages

Mounting and Connection Instructions Door controller module for MB
1.

System Description

1.1

General

The Door controller module enables mechanical locking technology to be combined with electronic
transmission of data and information.
The modules are equipped with an RS-485 bus that allows the use of up to 2 operating units/
readers so that the system can be operated at various points.
1.2

Functions - Overview:

Access control
(AC function)
A door locked by a door strike can be released via the operating unit and/or a button. In
conjunction with arming/disarming, the door lock release can be combined with the
disarming function.
Access control function via Trafficpoint RS-485
Trafficpoint in conjunction with MB-Secure in preparation
Wireless access control system that communicates with the DCM via radio.
One DCM can be equipped with up to 8 "radio doors" with access control function with
individual authorizations.
Hold-up alarm
A special hold-up code entered via the operating unit keypad triggers a hold-up alarm.
Control functions
Up to 100 control and switching functions can be invoked via the operating unit keypad.
Functions are assigned via the macro programming of the control panel.
1.3

System design

Betrieb
SAlarm SStörung
System-
Störung
Bereiche
Einbruch
7
8
9
B
wählen/
A
Meldungen
Ü
ansehen
ansehen
B
S
Sabotage
E
O
R
N
D
Gruppen
Überfall
4
A
F
5
E
6
G
ansehen/
F
Zusatz-
L
R
sperren
funktionen
Pol.-Notruf
L
F
F
U
U
N
Melder
Eingabe
Info 1
1
N
2
K
3
M
ansehen/
E
Quittierung
K
I
T
sperren
Bedienende
Info 2
T
I
O
O
N
ja
Info 3
N
nein
ALARMSTOP
Intern
0
unscharf
scharf-
AUS
löschen
EIN
schalten
Info 4
Alarmzentrale
561-MB100
Z
A509
024X
VdS
- Zulassungs-Nr.
Control panel
MB24 / MB48 / MB100.10
Opening contact
Passive glass breakage sensor
Bolt switching contact
Cover contact - external reader
Conditions:
Control panel:
WIMFEM Advanced:
(Conditions for radio system:
see Chapter 2.2)
(See following chapters for details)
Door controller
BUS-2
module
023350.17
+
from V10.xx
from
V09.xx
Up to 8 Trafficpoint RS-485
(Details see Chapter. 2.2.)
Door release button
F
I
1
2
3
4
5
6
7
8
9
1
2
3
3
r
0
ABC
DEF
4
5
6
GHI
JKL
MNO
F
7
8
9
PQRS
TUV
WXYZ
3
i
r
0
Up to 2 operating units/readers on RS-485 bus (details see 4.)
Door strike
7
8
9
4
5
6
1
2
3
OFF
0
ON
TBS
XS Pro cylinder
XS Pro fitting
Up to 8 per module
23
TBS

Advertisement

Chapters

Table of Contents
loading

Table of Contents