1-12. Periodic Inspection and Periodic Replacement Parts
Parts that must be periodically inspected and replaced are as shown in the table below.
Parts name
Description
Lithium battery
Replace the lithium battery every five years (rough standard) or when the
(UP-X898M only)
date is significantly shifted even after it is set.
. Be sure to use IEC-60086-4 certificated products as a lithium battery.
Use a lithium battery (CR2032 type):1-528-174-72 when replacing the lithium battery. (Only UP-X898MD)

1-13. Print Size

1-13-1. Rough Standard of Print Size

1. When a video input signal is printed (Only UP-X898MD)
Paperfeed direction
Width
SCAN
SIDE
NORMAL
OFF
ON
WIDE1
OFF
ON
WIDE2
OFF
ON
. The tolerance of length is width ?0.5 mm and height ?1.0 mm.
. When MULTI is valid, the size per screen is a value of 1/2, respectively.
2. When a digital (USB) input signal is printed
Paper size
Width
960 x 1280
99.8
1280 x 1280
99.8
1920 x 1280
99.8
3840 x 1280
99.8
4096 x 1280
99.8
. The tolerance of length is width ?0.5 mm and height ?1.0 mm.
1-30 (E)
Height
NTSC
ASPECT
Width
1:1
90.0
4:3
90.0
1:1
92.7
4:3
92.7
1:1
94.4
4:3
94.4
1:1
96.0
4:3
96.2
1:1
95.5
4:3
95.5
1:1
99.0
4:3
99.0
Height
74.9
99.8
149.8
299.5
319.5
PAL
Height
Width
93.8
90.0
70.5
90.0
90.2
92.3
118.0
92.3
96.8
94.4
72.7
94.4
94.4
95.7
124.3
95.7
99.7
95.5
75.0
95.5
96.7
98.0
125.6
98.0
Refer to
Section 1-10
Height
93.0
68.5
91.3
121.5
96.5
71.0
95.8
127.3
98.2
72.8
96.0
128.7