The device comes with 4 label stickers that contain a Unique identification code (UID) that is hexadecimal formatted in
4 bytes. An example UID is 45 90 DB FA. It is advised to stick one sticker on the module and one sticker on the luminary
that the module will be fitted in. The two remaining stickers may be placed on a printed floor plan, text lists etc.
MaxLED (See pictures on page 1):
1. Disconnect mains from the luminaire, slide the luminaire of the bracket. Remove the top lid.
2. Disconnect the battery and connect the internal extension antenna cable to the WL Module.
3. Plug the module.
4. Screw on the antenna.
5. Reconnect the battery and confirm LED operation.
6. Refit the top lid, assemble the luminaire and reconnect mains.
ExiLED (See pictures on page 2):
1. Screw on the extension antenna cable.
2. Disconnect mains from the luminaire, slid and open the luminaire case, (ref. ExiLED inst. manual) and disconnect the
battery. Plug the module.
3. Remove cap.
4. Remove nut and washer from the antenna cable and pass the cable through the side hole.
5. Tighten the nut and washer from the outer side (tool recommended). Make sure there are no sharp bends on the
antenna cable.
6. Screw on the antenna.
7. Reconnect the battery and confirm LED operation. Assemble the luminaire and reconnect mains.
You are now ready to setup the module for network communication. For network setup refer to the wireless network
comissioning manual.
Function
This device has three indication LEDs.
Top LED (green): RF connection status
Steady on:
Flashing 5 times per sec.:
Flashing 2 times per sec.:
Flashing 1 sec. on / 1 sec. off:
No light:
Middle LED (green):
Flashing 5 times per sec.:
Flashing 2 times per sec.:
Flashing 1 sec. on / 1 sec. off:
Flashing 2 sec. on / 2 sec. off:
Bottom LED (red): Indicates initialization
Flashing 5 times per sec.:
Flashing 2 times per sec.:
Button functionality
Short press:
Press more than 2 sec.:
At the end of their useful life the
packaging and product should be
disposed of via a suitable recycling
centre.
Do not dispose of with your normal
household waste.
Do not burn.
Honeywell Life Safety AS, Postboks 263, 1372 Asker
The device has established direct connection to a Gateway Device, and at least one
more Gateway Device is available for alternate routing (false condition).
The device has established direct connection to a single Gateway Device.
The device has established connection to a Router Device, and at least one more
Router Device is available on the same hop level, as an alternate route
(redundant connection).
The device has established connection to a single Router Device, and no alternatives
exist on the same hop level.
The device is disconnected.
Received signal strength (RSSI)
RSSI is very good.
RSSI is good.
RSSI is acceptable for reliable communication.
RSSI is not acceptable for reliable communication.
The module is not initialized correctly. In this case you have to press for more than
2 seconds the push button, in order to re-initialize the module.
The module is working properly.
A status message will be issued to the gateway device of the wireless network.
The router module will restore to its factory default settings. This is extremely useful
in case of an error setting during wireless network installation.
Technical description
Part no.
Operation voltage
Power Consumption
Ambient temperature range
Relative Humidity
IP Rating
Plug-in Module Wireless Exi-/MaxLED T2
138091.17
2.7-3.3V DC
< 0.2W
o
5 to 40 C
< 95%
IP20