3.4 Replacement of Lamp

CAUTION
A
Disconnect the electrical supply of
the hood. Leave the lamps to cool
down first because they could burn
your hands when they are hot.
(Figure 4)
Remove the aluminium cartridge filter. Re-
move the defective bulb and replace with
a new one with the same rating (Figure 4).
Bulb
Bulb Power (W)
Holder / Socket
Bulb Voltage (V)
Size (mm)
ILCOS Code
10 / EN
MAX 3 W
3
E 14
220 - 240
35 x 100
DRBB/F-3-220-
240-E14-35/100
3.5 Operation with Flue
Connection
Vapour
through the flue duct, which
is fastened to the connec-
tion head on the hood.
The diameter of the flue duct must be the
same as the connection ring. In horizontal
settings, the pipe has to have a slight up-
ward slope (around 10º) so that the air can
exit the room easily.
3.6 Operation
without Flue
Connection
Air is filtered through the carbon filter and
recirculated in the room. Carbon filter is
used when it is impossible to use a flue in
the house.
In flueless use, remove the flaps inside the
flue adapter.
Remove the Grease Filter . To install the
carbon filter, fit the filter to the tabs by cen-
tring it on the plastic piece on both sides of
the fan body. tighten it by turning right or
left.
Replace aluminium Grease Filter .