HP AdvanceStack 10Base-T Hub-12 Installation And Reference Manual page 54

Hide thumbs Also See for HP AdvanceStack 10Base-T Hub-12:
Table of Contents

Advertisement

Hub Reference
Port LEDs (green)
port on the hub, twisted-pair, the AUI/Xcvr port, and the ThinLAN port.
Each port LED indicates the status of the port associated with it.
Port Type
LED State
Twisted-pair
On
Link beat is detected from the attached node.
Off
The port is not receiving the link beat signal from the attached node.
Flashing
The port has been auto-segmented. The Fault LED will also be flashing at the same rate.
Slowly *
See "Auto-Segmentation" later in this chapter.
Flashing
The port has experienced a security violation. The Security LED will also be flashing at the
Rapidly **
same rate. See "Security Features" later in this chapter.
ThinLAN
On
– The port is enabled and it is not auto-segmented.
Off
EITHER:
– The port has been disabled through HP Stack Manager or a network management
station, OR,
– Thinwatch is disabled (the default setting) and the port is auto-segmented
because of an excessive collision condition. The default setting for Thinwatch is
"disabled"–Thinwatch can be enabled through HP Interconnect Manager or the
ASCII console interface with the HP Ethernet SNMP Module.
Flashing
The port has been auto-segmented and Thinwatch is enabled. The Fault LED will also be
slowly *
flashing at the same rate. See "Auto-Segmentation" later in this chapter.
Flashing
The port has experienced a security violation. The Security LED will also be flashing at the
Rapidly **
same rate. See "Security Features" later in this chapter.
AUI / Xcvr
On
The AUI/Xcvr port is enabled and not segmented. (This LED will always be on under these
conditions, even if this port is not being used.)
Off
The port has been disabled through HP Stack Manager or a network management station.
Flashing
The port has been auto-segmented. The Fault LED will also be flashing at the same rate.
slowly *
See "Auto-Segmentation" later in this chapter.
Flashing
The port has experienced a security violation. The Security LED will also be flashing at the
Rapidly **
same rate. See "Security Features" later in this chapter.
*
The slow flash rate is approximately once each 1.5 seconds.
** The rapid flash rate is approximately 3 times each second. This condition can exist only if an SNMP Module is
installed in the hub.
Reset Button
power-on self-test. It is recessed to prevent accidental resets. Use a pen
point or straightened paper clip to depress the button. For a description
of the effect of this reset, see "Resetting the Hub" in chapter 4, "Trou-
bleshooting".
3-4
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
There is an LED associated with each network
Meaning
The Reset button resets the hub and performs the

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hp advancestack 10base-t hub-24Hp advancestack 10base-t hub-48Hp j2600aHp j2601bHp j2602b

Table of Contents