Test Oil Tank; Cooling The Test Oil; Heating The Test Oil - Bosch EPS 625 Original Instructions Manual

Injection pump test bench
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 38
en
50 | EPS 625 | Product description
3.6

Test oil tank

1
2
4
Fig. 13:
Test oil tank
1 Test oil tank cover
2 Fasteners for oil tank cover
3 Test oil tank
4 Temperature probe
The test oil tank, mounted on the frame of the EPS 625,
has a capacity of 50 lts.
To access the test oil tank,
open the rear bottom panel (Fig. 1, Pos. 16).
A test oil heater is provided for heating the test oil.
To measure the test oil temperature, a temperature
probe (Fig. 13, Pos. 4) is provided. An oil level sensor is
provided to prevent dry running of the tandem pump.
i
There must be a minimum quantity of 30 lts of test
oil in the test oil tank. This is to ensure that there is
enough test oil during operation.
During calibration, the test oil is routed back from the
fuel injection pump to the test oil tank.
|
1 689 988 262
2017-12-26
3
3.6.1

Cooling the test oil

1
2
3
Fig. 14:
Inlet and outlet for cooling water
1 Heat exchanger
2 Cooling water outlet
3 Cooling water inlet
The test oil is cooled by a heat exchanger
(Fig. 14, Pos. 1). The test oil flows through the cooling
pipes and dissipates heat to the cooling water.
The test oil temperature is measured by the tempera-
ture sensors and is controlled by the cooling water sup-
plied to the heat exchanger. The supply of cooling water
is controlled by the logic board through solenoid valves.
i
See chapter 9 for details on requirements for cooling
water.
3.6.2

Heating the test oil

The test oil is heated by an electrical resistance heater
installed in the test oil tank.
i
To prevent the risk of fire due to overheating of test
oil, adequate safety measures have been provided.
The time required for heating the test oil from room
temperature to 40 °C depends on the amount of test oil
in the tank. The test oil heating cuts in immediately af-
ter starting the EPS 945 software to warm the test oil.
i
For further information, refer to the "EPS945" Online
Help.
The temperature sensors continuously monitor the tem-
perature.
Robert Bosch GmbH

Advertisement

Table of Contents
loading

Table of Contents