Download Print this page
Zamel RZB-03 Instruction Manual

Zamel RZB-03 Instruction Manual

Roller blinds wireless control set
Hide thumbs Also See for RZB-03:

Advertisement

Quick Links

CoNNECtioN
LOCAL
LOCAL
CAutioN:
Local switches connection (LoCAL) is optional.
APPLiCAtioN
Radio flush dimmer RNK-02 operating roller
blind controller SRP-02 (roller blind opening /
closing). The above mentioned transmitter can
be added to any number of receivers.
The ZAMEL company
characterised with this sign
WARRANtY CARD
There is 24 months guarantee on the product
1. ZAMEL provides a two-year warranty for its products.
2. The ZAMEL warranty does not cover: a) mechanical defects resulting from transport, loading / unloading or other circumstances
b) defects resulting from incorrect installation or operation of ZAMEL products; c) defects resulting from any changes made by CUS-
TOMERS or third parties, to products sold or equipment necessary for the correct operation of products sold; d) defects resulting
from force majeure or other aleatory events for which ZAMEL is not liable; e) power supply (batteries) to be equipped with a device
in the moment of sale (if they appear);
3. All complaints in relation to the warranty must be provided by the CUSTOMER in writing to the retailer after discovering a defect.;
4. ZAMEL will review complaints in accordance with existing regulations.;
5. The way a complaint is settled, e.g. replacement of the product, repair or refund, is left to the discretion of ZAMEL.
6. Guarantee does not exclude, does not limit, nor does it suspend the rights of the PURCHASER resulting from the discrepancy
between the goods and the contract.
Salesman stamp and signature, date of sale
SRP-02 MouNtiNG
1. Disconnect power supply by the phase fuse,
the circuit-breaker or the switch-disconnector
combined to the proper circuit.
2. Check if there is no voltage on connec-
tion cables by means of a special measure
equipment.
3. Connect the cables with the terminals in ac-
cordance with the installing diagram.
4. Install SRP-02 device in installation cable box.
5. Switch on the power supply from the mains.
RNK-02 FuNCtioNiNG, MouNtiNG
By pressing the button, the transmitter sends a
signal with 868,32 MHz frequency which controls
EXTA FREE receivers. Device programming
procedure (adding a transmitter to a receiv-
er's memory) is described in particular EXtA
FREE manual instructions. The device range
(up to 250 m depending on a receiver) can be in-
creased by means of a retransmitter or few RTN-
01 retransmitters. The device can be mounted in
any place by means of double-sided adhesive
tape or two wall plugs (5x(3x30) mm.
Mounting by means of wall plugs:
1. Remove the button - to do it press the button
on one side, and on the other side put a screw-
driver into a slot and lift up the button.
2. Find a place on the wall to mount the transmit-
ter, make two holes corresponding mounting
holes from the transmitter's base.
3. Set wall plugs in the holes.
4. Fix the base by means of screwing screws into
wall plugs.
5. Place the button again.
BAttERY CHANGE
Battery discharge status is signalled by sev-
eral LED red diode flashes during transmis-
sion time.
1. Remove the button (mounting - point 1).
2. By means of a screwdriver lever up the printed-
circuit board releasing the bottom latch and re-
move it from the base.
3. Remove the battery from the latch.
4. Mount a new battery. Watch battery polari-
sation marked on the latch. Wrong battery
mounting may cause device damage.
5. Put the removed printed-circuit board back in
the base.
6. Put back the button.
CAutioN:
While changing the battery, it is suggested to
press any of the buttons for about 5 seconds
before putting it into a latch. Next press trans-
devices which are
mission button several times to check its op-
eration. if the transmitter does not work prop-
can cooperate
with each other.
erly repeat the battery change procedure.
RZB-03 WIRELESS CONTROL SET
– ROLLER BLINDS CONTROL
ul. Zielona 27, 43-200 Pszczyna, Poland
tel. +48 (32) 210 46 65, fax +48 (32) 210 80 04
www.zamelcet.com, e-mail: marketing@zamel.pl
DESCRiPtioN
tECHNiCAL DAtA
SRP-02 controller is used to control
roller blind drives with 230V AC motor with
a limit switch. The device realises roller
blinds local and central control functions
and it has the possibility of comfort mode
adjustment. Comfort modes are used to
adjust roller blinds position (height level)
and to memorise the height level. Central
Nominal power consumption:
mode is used in case of a totally closed
or opened roller blind or a group of roller
blinds with different position level.
Maximum number of remote controls:
Maximum movement time of roller blind:
Maximum time of roller blind movement:
Optic signalling of transmitter's operation:
FEAtuRES
Motor power supply terminals:
● Complete
set
of
wireless
control
(2–channel button radio transmitter
RNK-02 and radio roller blinds controller
Number of terminal clamps:
SRP-02),
Section of connecting cables:
● used in wired and wireless control of
Ambient temperature range:
roller blind, sunblind and gate drives,
(electric motors of 230V AC),
● wired local control inputs,
● easily installed in Ø60 mm junction box,
● energy-saving device, possibility of con-
stant work,
● two comfort modes - upper and bottom
(memory of roller blind height level),
● possibility of cooperation with any roler
blind switch (which is not equipped in
backlight elements)
The device is designed for
APPEARANCE
single-phase installation and
must be installed in accord-
ance with standards valid in
Local wired control terminals
a particular country. The de-
(upward movement , downward movement )
vice should be connected ac-
CAutioN!
cording to the details included
Roller blind motor terminals
in this operating manual. Installation, connection
(upward movement , downward movement )
and control should be carried out by a qualified
Input (supply) terminals (L, N)
electrician staff, who act in accordance with the
service manual and the device functions.
In case of casing dismantling an electric shock
may occur, and the guarantee is lost then. Before
Optic signalling of receiver's operation
installation make sure the connection cables are
Programming push-button
not under voltage. The cruciform head screwdriv-
er 3,5 mm should be used to instal the device. Im-
Optic signalling
proper transport, storage, and use of the device
of transmitter's operation
influence its wrong functioning. It is not advisable
to instal the device in the following cases: if any
Push-button
device part is missing or the device is damaged
or deformed. In case of improper functioning of
the device contact the producer.
The symbol means selective
collecting of electrical and electronic
equipment.
It is forbidden to put the used
equipment together with other waste
MANUAL INSTRUCTION
ZAMEL Sp. z o.o.
RNK-02
SRP-02
Input (supply) terminals:
-
Input rated voltage:
3 V DC (CR2032 battery)
Battery life:
3 ÷ 5 years
Input voltage tolerance:
-
+10 ÷ -15 %
Nominal frequency:
-
-
0,4 W („stand-by" mode) / 0,7 W (roller blind movement)
Transmission:
radio 868,32 MHz
Coding way:
unidirectional
Coding:
addressing transmission
-
Range:
up to 250 m in the open area
-
-
1 ÷ 120 sec (every 0,1 sec)
LED red diode
Local control terminals:
-
LOCAL (up), (down)
-
(up), (down)
Relay contact parameters:
-
2NO 5A/250V AC AC3 1250 VA
-
-
up to 2,5 mm
-10 ÷ +55
o
C
Operating position:
free
Casing mounting: wall plugs, double-sided adhesive tape
installation cable box Ø60 mm
Casing protection degree:
IP20 (EN 60529)
Protection level:
III
Overvoltage category:
-
Pollution degree:
2
Surge voltage:
-
1 kV (EN 61000-4-5)
Dimensions:
90 x 80 x 11,5 mm
47,5 x 47,5 x 20 mm
Weight:
0,038 kg
Reference standard:
ETSI EN 300 220-1
EN 60669, EN 60950,
ETSI EN 300 220-2
L, N
230 V AC
-
50 / 60 Hz
32
120 sec
6
2
II
II
0,039 kg
EN 61000
VER. 003_20.05.2011

Advertisement

loading

Summary of Contents for Zamel RZB-03

  • Page 1 TOMERS or third parties, to products sold or equipment necessary for the correct operation of products sold; d) defects resulting from force majeure or other aleatory events for which ZAMEL is not liable; e) power supply (batteries) to be equipped with a device the device contact the producer.
  • Page 2 SRP-02 oPERAtioN RADio tRANSMittERS DELEtioN Pressing shortly the programmed push-button in local mode (<2 sec.) or roller blind switch (optional) causes the roller blind moves. Another short pressing of the same push-button or the switch causes the roller blind stops at a required level. Pressing the push-button or the switch longer (>2 sec.) causes comfort mode activates (the roller blind moves in required direction and stops according to the adjusted time).

This manual is also suitable for:

Rnk-02Srp-02