1.1 Introduction

This document contains information for installing, programming, and operating the FDU-80 Remote Fire Annunciator.

1.2 UL 864 Compliance

1.2.1 UL 864 9th and 10th Edition
Per the UL Continuing Certification Program, UL 864 9th edition fire alarm control equipment will retain certification after the
rollout of UL 10th edition (12/2/2018).
Installations of UL 864 10th Edition certified equipment are permitted to use UL864 9th Edition certified equipment when
approved by the local Authority Having Jurisdiction (AHJ).
For product compliance, refer to the UL/ULC listing cards located on the UL online certification directory.
https://iq.ulprospector.com
The following products have not received UL 864 9th Edition certification and may only be used in retrofit applications. Operation of the
FDU-80 with products not tested for UL 864 9th Edition has not been evaluated and may not comply with NFPA 72 and/or the latest edi-
tion of UL 864. These applications will require the approval of the local Authority Having Jurisdiction (AHJ).
• FireWarden NFW-100
• AFP-300/400
• NFS-640
1.2.2 Programming Features Subject to AHJ Approval
This product incorporates field-programmable software. The features and/or options listed below must be approved by the local AHJ.
This product incorporates field-programmable software. In order for the product to comply with the requirements in the
Standard for Control Units and Accessories for Fire Alarm Systems, UL 864, certain programming features or options must be
Program feature or option
Piezo Enable/Disable

1.3 Related Documentation

The table below provides a list of document sources (manuals) containing additional information regarding the fire alarm control panels
and components that ACS annunciators can be connected to. The NOTIFIER document (DOC-NOT) chart provides the current docu-
ment revision.
6

Section 1: Overview

limited to specific values or not used at all as indicated below.
Permitted in UL 864
(Y/N)
Y
Document Name
Notifier Device Compatibility Document
NFS2-640 Fire Alarm Control Panel
NFS-320 Fire Alarm Control Panel
FireWarden NFW-100-2 Instruction Manual
FCPS-24S6/8 Instruction Manual
VeriFire® Tools CD help file
NFS-640 Fire Alarm Control Panel (UL 8th)
AFP-300/AFP-400 Installation Manual (UL 8th)
FireWarden NFW-100 Instruction Manual (UL 8th)
Possible settings
SW1-2 ON = Piezo Enabled
SW1-2 OFF = Piezo Disabled
P/N
15378
52741LD
52745LD
52778
51977
VERIFIRE-TCD
51332, 51333, 51334
50253
52299
FDU-80 Instruction Manual — P/N 51264:C2 4/24/2019
Settings permitted
in UL 864
SW1-2 ON = Piezo Enabled