Sony XBR-65Z9D Service Manual page 9

Gn2tr chassis
Hide thumbs Also See for XBR-65Z9D:
Table of Contents

Advertisement

[SELF DIAGNOSTIC SCREEN DISPLAY]
Format of error timestamps
YYMMDDhhmmss (in UTC)
Example:
120823132523 -> Aug 23 2012 13:25:23 UTC
* Only when time is set, an error timestamp
is saved.
• Panel Operation Time is recorded every 30 min,
but Total Operation Time is recorded every 1 hr .
Therefore, the panel op. time might become larger than the total op. time.
Total Operation Time [hr] – Boot Count – Panel Operation Time [hr]
For errors with symptoms such as "power sometimes shuts off" or
"screen sometimes goes out" that cannot be confirmed,
it is possible to bring up past occurrences of failure for confirmation on the screen:
In standby mode, press buttons on the remote commander sequentially in rapid
succession as shown below:
Since the diagnostic results displayed on the screen are not automatically cleared, always check the self-diagnostic screen.
After you have completed the repairs, clear the result display to "0".
Panel Operation Time clear :
Timestamps and Error Count clear :
Total Operation Time and Boot Count clear:
To exit the Self Diagnostic screen...
*If you want to finish service mode app, do AC OFF/ON →Service mode app is disabled perfectly
*if you want to move home menu, push <HOME>button →Service mode app do background(not disable perfectly)
XBR-65/75/100Z9D
Back
002
003
003
003
003
Smart Core Red LED
blinking count
004
004
005
005
006
007
008
00005
Press the Channel 7 => Channel 0 .
Press the Channel 8 => Channel 0 .
Press the Channel 9 => Channel 0 .
Error Item
SELF CHECK
MAIN POWER
000000000000
DC ALERT
000000000000
AUD ERR
150101000018
AUD ERR I2C
150101000123
TU DEMOD
150101000218
LD ERR
000000000000
BCM ERR
000000000000
TCON ERR
150101000504
P ID ERR
000000000000
BACKLIGHT ERR
000000000000
TEMP ERR
150101000200
4KBE ERR
000000000000
00414
00002
Error
timestamp for
last recorded
error
SELF DIAGNOSIS FUNCTION
Error count
<<
000000000000
000000000000
000
000000000000
000000000000
000
150101000018
150101000018
003
150101000045
150101000045
003
150101000223
150101000105
003
000000000000
000000000000
000
000000000000
000000000000
000
000000000000
000000000000
001
000000000000
000000000000
000
000000000000
000000000000
000
150101000002
000000000000
002
000000000000
000000000000
000
[Home]Exit
Error
Error
timestamp for
timestamp
second last
for 3rd last
recorded
recorded
error
error
9