Zenith 216666666 Installation And Operating Instructions Manual

Tudor 5/10 litre over/under-sink water heater telescopic spout accessory mono/solo/hero vented mixer tap

Advertisement

Quick Links

Zenith Tudor
Single point open outlet (vented) water heaters
Zenith Tudor 5 Litre over-sink water heater
21600
Zenith Tudor 10 Litre over-sink water heater
p Tud over-sink water heater
21620
Zenith Tudor 5 Litre under-sink water heater
216666666 Zip Tudor 5 Litre under-sink water heater
21610
Zenith Tudor 10 Litre under-sink water heater
216666666666utor 10 Litre under-sink water heate
21630
99032
99032
Telescopic Spout accessory for 21600 / 21620
Telescopic Spout accessory for 21000 / 21020
Mono vented mixer tap for 21610 / 21630
990399999994 Mono vented mixer tap fo66r 21010 / 21030
99079
Solo vented mixer tap for 21610 / 21630
919111088lo vented mixer tap for 21010 / 21030
99080
Hero vented mixer tap for 21610 / 21630
99050
99081
Hero vented mixer tap for 21010 / 21030
Installation & Operating Instructions
ä

Advertisement

Table of Contents
loading

Summary of Contents for Zenith 216666666

  • Page 1 Zenith Tudor 10 Litre over-sink water heater p Tud over-sink water heater 21620 Zenith Tudor 5 Litre under-sink water heater 216666666 Zip Tudor 5 Litre under-sink water heater 21610 Zenith Tudor 10 Litre under-sink water heater 216666666666utor 10 Litre under-sink water heate...
  • Page 2: Read These Warnings First

    Children should be supervised to ensure they do not play with the heater. The heater is unsuited for use by children or infirm people without supervision. If the power supply cord is damaged it must be replaced by a Zenith Service Provider or a qualified electrician.
  • Page 3: Installation Requirements

    Cold Water Supply from Tap Zenithp Tudor - Installation & Operating Instructions - 81333 - May 2003 Zenith Tudor - Installation & Operating Instructions - 81333 - July - 2004 Installation Requirements Before installing, ensure that the following are available: a) sufficient space to position the heater so there is 270 mm clear access under the heater (over-sink models) or 270mm above (under-sink).
  • Page 4 On over-sink models, the inlet and outlet are located on the base of the heater. On under-sink models, the inlet and outlet are located on the top of the heater. All Zenith Tudor water connections are via 15 mm compression fittings and must be made strictly as shown in the diagrams.
  • Page 5: Problem Solving

    Zip Tudor - Installation & Operating Instructions - 81333 - May 2003 Zenith Tudor - Installation & Operating Instructions - 81333 - July - 2004 Installation Procedure Continued Over-Sink Under-Sink Problem Solving Fault Possible cause No heat No power Faulty element...
  • Page 6: Operating Procedures

    Safety Cutout Should the heater over-heat, a manually resettable safety cutout will automatically turn the heating element OFF. The cutout must be reset by a Zenith Service Provider or a licensed electrician. Users should never reset the cutout without qualified assistance.
  • Page 7: Service Procedures

    Mixer Cartridge “Y” Zenithenithudor - Installation & Operating Instructions - 81333 - May 2003 Zenith Tudor - Installation & Operating Instructions - 81333 - July - 2004 Service Procedures This appliance may only be serviced by a suitably qualified technician.
  • Page 8: Warranty Information

    No costs are payable by the customer other than any mileage or travelling-time charges incurred by a Zenith Service Provider or the cost of removal, cartage and re-installation of any component of the appliance if it needs to be returned for repair its Distributor.