Switch Types - GE Zenith ZTS Series Quick Start Manual

Low-voltage automatic and manual transfer switches

Advertisement

Z enith ZTS Series Ordering Information
B 0
Z
MODEL / TYPE
CONTROL
PANEL
Z T S 0 0 0
B 0
Standard (Open Transition)
Entelli-Switch 250
Microprocessor
Control Unit
Z T S D 0 0
B 1
Delayed Transition
Horizongal bypass
Z T S C T 0
unit with MX250
Closed Transition
B 4
Z B T S 0 0
High withstand panel
with MX250
Standard (Open Transition) w/Bypass
Z B T S D 0
Delayed Transition w/Bypass
Z B T S C T
Closed Transition w/Bypass

Switch Types

• Standard: Unless otherwise noted, the
standard switch with quick transfer will
be supplied.
• Delayed Transition: When ordered as
the ZTSD , the delayed transition switch
offers time delay during transfer from one
position to the other. This is primarily for
transfer of large motor or inductive loads.
• Closed Transition: When ordered as the
ZTSCT , the closed transition switch offers
two basic modes of operation. During
a failure of one source or an out of specifi-
cation condition, the ZTSCT Model oper-
ates as a standard delayed transition
switch ( ZTSD Model). This sequence allows
clear separation of an unreliable source
from an available one.
• Bypass: When ordered as the ZBTS , the
bypass transition switch offers a draw-out
mechanism, with electrical and mechanical
interlocks for secure removal after load
bypass. In this way the transfer switch
and/or the control panel may be tested,
isolated and removed for maintenance
without load interruption.
Example
ZTSCT 0 B 00040 F - ZEC 01 ZVC 40 MSTD
This number string shows the correct format
for a ZTS Model Automatic Transfer Switch
with closed transition, an Entelli-Switch
250 microprocessor control unit, Utility -
Generator, 400 amps, 4 pole, NEMA Type 1
enclosure, 120/208V 3 φ , 4 wire, 60 Hz system
with the standard group of accessories.
*Available only on Bypass configuration
**
Available for 1600-3000A Non-bypass product ONLY.
APPLICATION
AMPERE S IZE SWITCHED
0 0 4
0
Utility - Generator
40 amps
0 0 8
U
Utility - Utility
80 amps
0 1 0
M
100 amps
**
Manual
0 1 5
G
150 amps
Gen to Gen
0 2 2
225 amps
0 2 6
260 amps
0 4 0
400 amps
0 6 0
600 amps
0 8 0
800 amps
1 0 0
1000 amps
1 2 0
1200 amps
1 6 0
1600 amps
2 0 0
2000 amps
*
2 6 0
2600 amps
3 0 0
3000 amps
4 0 0
4000 amps
UL 1008
Withstand
and Closing
Ratings
Please refer to
GE Publication
TB -1102.
Z E C
ENCLOSURE TYPE
POLES
B
0 1
Type 1 Enclosure
2 Poles
1 2
E
3 Poles
Type 12 Enclosure
3 R
F
Type 3R Enclosure
4 Poles
4 0
Type 4 Enclosure
4 X
Type 4X Enclosure
0 0
Open Style Unit
A
B
1
0
2
0
2
2
3
0
3
1
3
2
3
5
4
0
4
1
4
2
5
0
5
1
5
2
5
5
5
7
5
8
6
0
6
1
6
3
7
0
7
1
7
4
7
5
8
2
9
0
9
1
9
2
9
3
9
7
Note: Operating voltage must be specified at time of
order. Only the most common voltages are shown above.
Information subject to change without notice. Please verify all details with GE .
© 2018 General Electric Company All Rights Reserved
PB - 5066 (12/09)
Z V C
OPERATIONAL VOLTAGE
ACCESSORIES
A B
M
S
Consult Table Below
M
E
M
C
M
S
M
S
M
P
M
A
Then choose
additional accessories
Voltage Phase
Config.
120
1
2 wire
120/240
1
3 wire
110/220
1
3 wire
240
3
3 wire
208
3
3 wire
220
3
3 wire
139/240
3
4 wire
120/208
3
4 wire
127/220
3
4 wire
127/220
3
4 wire
480
3
3 wire
440
3
3 wire
440
3
3 wire
460
1
3 wire
480
1
2 wire
254/440
3
4 wire
575
3
3 wire
347/600
3
4 wire
575
1
2 wire
277/480
3
4 wire
277
1
2 wire
266/460
3
4 wire
460
3
3 wire
380
1
2 wire
240/416
3
4 wire
220/380
3
4 wire
220/380
3
4 wire
240/416
3
4 wire
380
3
3 wire
ssembled in the
A
GE D igital E nergy – Power Quality
830 W 40 th Street, Chicago, IL 60609 USA
800 637 1738 www.gepowerquality.com
T D
X E
O N
E N
P E
S G
N 0
Hz
60
60
50
60
60
50
60
60
60
50
60
60
50
50
60
60
60
60
60
60
60
60
60
50
60
60
50
50
60
USA

Advertisement

loading