Configuring Directly from
the Control Panel
Starting and Exiting Configuration
Mode
To start configuration mode, press and hold the CONFIG
button so that the CONFIG button indicator LED lights.
To exit configuration mode, press and hold the CONFIG button
so that the CONFIG button indicator LED goes out. Any
changed setting is enabled (stored in non-volatile memory)
and then the CONFIG button LED goes out.
To configure multiple items consecutively, you can select the
next item to configure without exiting configuration mode after
setting each item using the master gain selection buttons.
Notes
• The CONFIG button LED indicator is lit during configuration
mode.
• The camera/CCU cannot be controlled from the unit during
configuration mode.
• Changed settings will be discarded if the unit is restarted
without first exiting configuration mode.

Setting the Control Panel

The following knobs, buttons, and display windows are used to
configure settings on the unit.
For the default settings, see "Control Panel Settings"
(page 14).
CONFIG button
ON button
SAVE button
CC (color
temperature
conversion)
filter selection
buttons
CC (color temperature
conversion) filter display window
1
Press and hold the CONFIG button to start
configuration mode.
2
Set the master gain display window to the number of
the item to set using the master gain selection
buttons.
For details about the numbers displayed in the master
gain display window, see "Control Panel Settings"
(page 14).
3
Set the CC filter display window to the number of the
item to set using the CC (color temperature
conversion) filter selection buttons.
The current value corresponding to the item number
displayed in the CC filter display window is shown in the
adjustment display window.
For details about the numbers displayed in the CC filter
display window, see "Control Panel Settings" (page 14).
Note
The CC filter selection buttons may not be required,
depending on the item being set. In this case, proceed to
step 4.
4
Display the desired setting in the adjustment display
window by turning the adjustment knob.
5
Press the SAVE button to apply the setting.
To configure another item, select the next item without
exiting configuration mode using the master gain selection
buttons.
The changed setting is not stored in non-volatile memory
when you press the SAVE button. Pressing and holding
the CONFIG button will store the setting and exit
configuration mode.
6
Press and hold the CONFIG button to exit
configuration mode.
Adjustment
display window
Adjustment
knob
Master gain
display window
Master gain
selection
buttons
13