Installation Instructions; Electrical Connections; Electrical Requirements - Zanussi ZHC605 Instruction Booklet

Zanussi instructrion manual ventilation hood zhc605, zhc705, zhc905
Table of Contents

Advertisement

It is dangerous to alter the specifi cations or attempt to modify this product in any way.
Technical Information
DIMENSIONS
ELECTRICAL SUPPLY:
SUITABLE FOR INSTALLATION
ABOVE:
DOUBLE INSULATED DO NOT EARTH

Electrical Requirements

Any permanent electrical installation must
comply with the latest I.E.E. Regulations and
local Electricity Board regulations. For your own
safety this should be undertaken by a qualifi ed
electrician e.g. your local Electricity Board, or a
contractor who is on the roll of the National
Inspection Council for Electrical Installation
Contracting (NICEIC).
Electrical Connection
Before connecting to the mains supply ensure
that the mains voltage corresponds to the
voltage on the rating plate inside the cooker
hood.

INSTALLATION INSTRUCTIONS

HEIGHT OF CANOPY:
HEIGHT OF CHIMNEY:
WIDTH OF CANOPY - ZHC 605:
WIDTH OF CANOPY - ZHC 705:
WIDTH OF CANOPY - ZHC 905:
DEPTH OF CANOPY:
GROSS - ZHC 605:
GROSS - ZHC 705:
GROSS - ZHC 905:
NET - ZHC 605:
NET - ZHC 705:
NET - ZHC 905:
VOLTAGE:
POWER CONSUMPTION:
FAN MOTOR:
LIGHT BULB:
ELECTRIC HOB:
GAS HOB:
SLOT-IN GAS COOKER
SLOT-IN ELECTRIC COOKER
Note: CE Marking certifi es that this appliance complies with the requirements
laid down in EEC directive 89:336. (Electromagnetic compatibility) and
subsequent modifi cations and Low Voltage directive 72/23/E.

ELECTRICAL CONNECTIONS

(UPPER SECTION) 20cm
(LOWER SECTION) 56cm
(2 x 40 W)
This appliance is fi tted with a 3 core mains
cable and must be permanently connected to
the electricity supply via a double-pole switch
having 3mm minimum contact gap on each
pole. A Switched Fuse Connection Unit to
BS1363 Part 4, fi tted with a 3 Amp fuse, is a
recommended mains supply connection
accessory to ensure compliance with the Safety
Requirements applicable to fi xed wiring
instructions.
This appliance conforms to BS 800: 1988 and
EEC Directive No. 78 308 regarding
suppression of radio and television
interference.
10
24cm
59,8cm
69,8cm
89,8cm
49cm
16kg
16,5kg
17,6kg
12,4kg
12,8kg
13,7kg
220-240 V 50Hz
230W
150W
80W
7KW (max)
10KW (max)
13.5KW (max)
12.4KW (max)