  • Page 2: For The Installer

    If you require guidance in the use of the appliance or require further information on Zanussi Products, please contact our Customer Care Department. For general enquiries concerning your Zanussi appliance or for further information, visit our website at http://www.zanussi.co.uk...
  • Page 3: Important Safety Information

    • Under no circumstances should you attempt to repair the appliance yourself. Repairs carried out by inexperienced persons may cause injury or more serious malfunction. Refer to your local Zanussi Ser- vice Force Centre. Always insist on genuine spare parts.
  • Page 4: Your Appliance

    OPERATING INSTRUCTIONS The cooker hood is designed to extract unpleasant odours from the kitchen, it will not extract steam. The appliance can be installed to recirculate or extract contaminated air. Cooker Hood Controls The cooker hood functions are controlled by three switches located on the underside of the hood immediately in front of the metal grease fi...
  • Page 5 To Operate Select the required fan speed and light if required. Recirculation In the recirculation mode the contaminated air enters the cooker hood through the grease fi lters. The air is cleaned by passing through the charcoal fi lters before being passed back into the kitchen through the grilles in either side of the chimney stack.
  • Page 6: Maintenance And Cleaning

    MAINTENANCE AND CLEANING Before carrying out any maintenance or clea- ning isolate the cooker hood from the mains supply. The cooker hood must be kept clean, as a build up of grease or fat can be a fi re hazard. External Cleaning Wipe the cooker hood frequently with warm soapy water using a mild detergent.
  • Page 7: Charcoal Filters

    MAINTENANCE AND CLEANING Charcoal Filters In the recirculation mode the charcoal fi lters absorb smells and unwanted odours. The charcoal fi lters cannot be cleaned, we recommend they should be replaced approximately every three months or more often if the hood is used for more than three hours per day.
  • Page 8: Something Not Working

    For general assistance with your appliance or for further information on Zanussi products please contact our Customer Care Department. Customer Care Department, Zanussi 55 - 77 High Street...
  • Page 9: Guarantee Conditions

    GUARANTEE CONDITIONS We Zanussi, undertake that if within twenty four months of the date of the purchase this Zanussi built-in appliance or any part thereof is proved to be defective by reason only of faulty workmanship or materials, the company will, at our option repair or replace the same FREE OF ANY CHARGE for labour, materials or carriage on condition that: •...
  • Page 10: Installation Instructions

    INSTALLATION INSTRUCTIONS It is dangerous to alter the specifi cations or attempt to modify this product in any way. Technical Information DIMENSIONS ELECTRICAL SUPPLY: SUITABLE FOR INSTALLATION ABOVE: Note: CE Marking certifi es that this appliance complies with the requirements laid down in EEC directive 89:336.
  • Page 11: Installing The Cooker Hood

    INSTALLING THE COOKER HOOD Please ensure that when the appliance is installed it is easily accessible to an engineer in the event of a breakdown. All installations must comply with the local authorities requirements for the discharge of exhaust air. Incorrect installation may affect the safety of this cooker hood.
  • Page 12 INSTALLING THE COOKER HOOD Clearance Height The cooker hood is designed to be fi tted over a cooking appliance at the clearance heights stated, providing the maximum output of the appliance beneath does not exceed the maximums quoted in the Technical Speci- fi...
  • Page 13: Fitting The Wall Brackets

    INSTALLING THE COOKER HOOD Fitting the Wall Brackets • Draw a vertical line on the supporting wall up to the ceiling, or as high as practical, at the centre of the area in which the hood will be installed. • Draw a horizontal line at 650 mm above the hob for installation without the back panel, or at height H (H=height of the visible part of the panel) for instal- lation with the back panel.
  • Page 14: Recirculation Mode

    INSTALLING THE COOKER HOOD Extraction (Ducted) The cooker hood is more effective when installed in the extraction mode (ducted to the outside). Venting kits may be purchased through your retailer or DIY store or using the enclosed form, and must be evacuated through an outside vent of ø125 (5ins) or ø150mm (6ins).
  • Page 15 INSTALLING THE COOKER HOOD Fitting the Upper Chimney • Slightly widen the two sides of the upper chimney and hook them behind the brackets item 7.2.1 ensuring they are correctly seated. • Secure the sides to the brackets using the 4 screws item 12c (2.9 x 9.5mm) supplied.