Sony BDX-D1000 Installation Manual
Sony BDX-D1000 Installation Manual

Sony BDX-D1000 Installation Manual

Mpeg decoder unit

Advertisement

Quick Links

MPEG DECODER UNIT
BDX-D1000
DESCRAMBLER BOARD
BDKP-D1003
DESCRAMBLER BOARD
BDKP-D1004
INSTALLATION MANUAL
1st Edition (Revised 5)
Serial No. 10001 and Higher: BDX-D1000
Serial No. 10001 and Higher: BDKP-D1003
Serial No. 10001 and Higher: BDKP-D1004

Advertisement

Table of Contents
loading

Summary of Contents for Sony BDX-D1000

  • Page 1 MPEG DECODER UNIT BDX-D1000 DESCRAMBLER BOARD BDKP-D1003 DESCRAMBLER BOARD BDKP-D1004 INSTALLATION MANUAL 1st Edition (Revised 5) Serial No. 10001 and Higher: BDX-D1000 Serial No. 10001 and Higher: BDKP-D1003 Serial No. 10001 and Higher: BDKP-D1004...
  • Page 2 à moins d’être qualifié pour en effectuer d’autres. Pour toute réparation faire appel à une personne compétente uniquement. Attention-when the product is installed in Rack: (For BDX-D1000) 1. Prevention against overloading of branch circuit When this product is installed in a rack and is...
  • Page 3: Table Of Contents

    ISR......................3-4 (E) 3-3-1. Functions Overview ............. 3-4 (E) 3-3-2. Usage of ISR Functions ............3-5 (E) 3-3-3. Supported Commands ............3-8 (E) 3-3-4. Functions of Commands ............3-8 (E) 3-4. Indicator on the Front Panel ..............3-10 (E) 1 (E) BDX-D1000...
  • Page 5: Manual Structure

    Manual Structure Purpose of this manual This manual is the installation manual of the BDX-D1000 MPEG Decoder Unit and the following optional boards. . Descrambler Board BDKP-D1003 . Descrambler Board BDKP-D1004 This manual is intended for use by trained system and service engineers, and describes information regarding installation.
  • Page 7: Installation

    2 Plug holder (Black) 2-990-242-01 Plug holder is included in DK-2401 (UK). The rear side of the BDX-D1000 should be at least 20 cm (8 inches) away from walls for ventilation and maintenance. AC inlet Do not block the ventilation holes.
  • Page 8: External Dimensions

    The BDX-D1000 can be mounted in a 19-inch standard rack. . When the BDX-D1000 or the peripheral equipment is mounted in a 19-inch standard rack, it is recom- mended to install a ventilation fan to prevent a temperature rise in the rack.
  • Page 9 : The BDX-D1000 comes with the eight screws. The two screws of them are spare. 4. Attach the inner rails to the BDX-D1000 using the six Be sure to use the RMM-30 Rack Mount Rail. screws (B4x8) supplied with the BDX-D1000.
  • Page 10 Distance to the center of the side rail Height of the unit mounted in a rack Unit : mm . Be sure to mount the BDX-D1000 in the rack with two or more persons. Trying to handle this job by one-person could occur to injury.
  • Page 11: Matching Connectors And Cables

    When connecting cables to various connectors on the rear panel at the time of installing or servicing, connect the following connectors/cables or their equivalents. BDX-D1000 Matching Connector/Cable Panel Indication Connector/Cable SONY Part No. REF. VIDEO BNC 75 Z, male 1-569-370-12 BIT STREAM INPUT BNC 75 Z, male...
  • Page 12: Input And Output Signal Of Connector

    PSYNC A (=Packet sync A) Cable Shield — Clock B System GND — Data 7B (MSB) Data 6B Data 5B Data 4B Data 3B Data 2B Data 1B Data 0B DVALID B (=Data valid B) PSYNC B (=Packet sync B) 1-6 (E) BDX-D1000...
  • Page 13: Switch Setting Of Connector Panel

    *2 : For any unit with a serial number 10001 to 10420, the connector is indicated as RS-232C. 4 10BASE-T (8-pin Modular jack) – External view – Pin No. Signal TXD + TXD _ RXD + — — — — RXD _ — — — — 1-7 (E) BDX-D1000...
  • Page 14: Settings Of Internal Switches

    S403 (J-10) switch is not used. S703 (C-10) 20 . After this setting is changed, turn the power off and on (MONITOR) again. S704 (A-10) 20 (MONITOR) *1: Serial No.10001 through 11000 *2: Serial No.11001 and Higher 1-8 (E) BDX-D1000...
  • Page 15: Dec-99 Board (Suffix -14 And Higher)

    ON : Freeze mode Freezes the picture that is shown just before the received stream is interrupted. OFF : Blackout mode Turn the screen gradually into black when the received stream is interrupted. Factory setting : ON (lower position) 1-9 (E) BDX-D1000...
  • Page 16: Dec-99 Board (Suffix -11 Through -13)

    Factory setting After this setting is changed, turn the power off and on again. S600 S200-5 (A-5) : REMOTE/LOCAL Select switch Selects whether the operation of the BDX-D1000 is controlled by an external computer via Ethernet or by S302 Factory setting using the menu and the buttons on the front panel.
  • Page 17: Settings Of Parameters

    Ethernet S200-5 (A-5) : REMOTE/LOCAL Select switch . VIDEO CONTROL menu (For your purpose) Selects whether the operation of the BDX-D1000 is . AUDIO CONTROL menu (For your purpose) controlled by an external computer via Ethernet or by using the menu and the buttons on the front panel.
  • Page 18 1-9. Settings of Parameters SYSTEM INFO. menu When using the Ethernet, set the IP address. SYSTEM INFO. MODEL NAME BDX-D1000 SERIAL NO. 10001 SOFT VER. 1.00 IP ADDRESS 192. IP ADDRESS (GATEWAY) SUBNETMASK 255.255.255. VIDEO CONTROL menu Set the requirements of video output for your purpose.
  • Page 19: Installation Of Optional Boards

    The assignments of slots are as follows: Slot No. Front side Rear side DEC-99 + SCR-7 (BDKP-D1003) TSI-2 SCR-8 (BDKP-D1004) — DIO-48 DAC-31 BF-72 <Front side> Slot No. SCR-7 (BDKP-D1003) DEC-99 + SCR-8 (BDKP-D1004) DAC-31 <Rear side> Slot No. TSI-2 DIO-48 BF-72 2-1 (E) BDX-D1000...
  • Page 20: Bdkp-D1003/D1004 Installation

    BVTT 3x6 15. Close the front panel. Board retainer Install 16. Tighten the locking screw. Board retainer Confirmation after installation BVTT Remove There is no necessity to confirm/adjust after SCR-7/8 BVTT board installing. Serial No. 10001 through 11000 2-2 (E) BDX-D1000...
  • Page 21: Service Overview

    When washing the filter, be sure to dry it well. . Filter: 3-613-550-01 6. After cleaning, fasten the filter to the tapes. If the BDX-D1000 is kept on operating with too dusty of the filter, the temperature inside the unit getting rise. This may cause a fire.
  • Page 22: Description Of Internal Indicators

    Lights up when a stream has a packet length of 188 bytes. D205 (A-4) (green): 4 : 2 : 2 Detection indicator Lights up when a stream has a chroma format of 4 : 2 : 2. 3-2 (E) BDX-D1000...
  • Page 23 Lights up when data is transmitted to Ethernet port. D701 (F-2) (green): LAN Link indicator Lights up when Ethernet port of the BDX-D1000 links to the hub or Ethernet port of the external computer. D702 (F-2) (red): LAN Collision Detect indicator Lights up when a collision is detected at Ethernet port.
  • Page 24: Dec-99 Board (Suffix -11 Through -13)

    The BDX-D1000 corresponds to the ISR (Interactive Status Reporting) function. D700 D701 Using this function, the state of the BDX-D1000 and the D702 contents of a generated error can be intensively monitored and managed on the monitor screen of a personal computer.
  • Page 25: Usage Of Isr Functions

    Center. The preparation below is required when managing the BDX-D1000 by ISR. 1. Connect a personal computer to the RS-232C connec- tor (D-sub 9-pin) of the BDX-D1000 using a RS-232C cross cable. Personal computer BDX-D1000 rear panel RS-232C cross cable 2.
  • Page 26 3-3. ISR Information of ISR Connector Prepare a cable referred to the following connection. In case of direct connection with a personal computer Signal Signal DB25 Signal Signal 3-6 (E) BDX-D1000...
  • Page 27 3-3. ISR In case of connection with a host computer via LAN (Terminal Server: 6-pin port) The connection will change according to the maker of terminal server. Terminal Server RJ12 (Modular type) 3-7 (E) BDX-D1000...
  • Page 28: Supported Commands

    Virtual machine type : NONE VM sub-address : NONE Destination : NONE * * * * * TST ##### (Test) This command instructs the BDX-D1000 to execute the specified self-diagnostics. Test numbers and descriptions are as follows: Test No. Description DEC Board...
  • Page 29 This setting data will be reflected in “Device ID” of response to “* IDN?” command. * * * * * CMDERR? (Command Error Query) When the setting is complete, the BDX-D1000 returns When an error detected by the error check for received “* ATN:OPC;”.
  • Page 30: Indicator On The Front Panel

    DEC-99 board or the MB-762 board. → Replace the DEC-99 board or MB-762 board. (Refer to the Section 1-6-1 or 1-6-3 in maintenance manual.) 3. Put S200-6 on the DEC-99 board to original position. 3-10 (E) BDX-D1000...
  • Page 31 The material contained in this manual consists of information that is the property of Sony Corporation. Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described in this manual without the express written permission of Sony Corporation.
  • Page 32 BDX-D1000 (SY) BDKP-D1003 (SY) Printed in Japan Sony Corporation BDKP-D1004 (SY) J, E 2001. 12 11 B&P Company 3-200-104-06 ©1998...

This manual is also suitable for:

Bdkp-d1003Bdkp-d1004

Table of Contents