Weekly Schedule Timer - Toshiba RBC-EXW21E2 Quick Reference

Super digital inverter remote controller
Table of Contents

Advertisement

5. Weekly schedule Timer

Type Name
: TCB-EXS21TLE
Part No.
: Not assigned
Substitution
: NO
Type of Remote : Schedule Timer
Reference
: NO
Product used
: VRF
Note
: *4 way
*Duct
*Ceiling
4
120
How to wire the remote controller
Wiring diagram
Power terminal
Schedule
timer
Clamp filter
System diagram
: Terminal board
DC12V
Wired
Schedule
remote
timer
4 wires
controller
16
Category
DI
OK
SDI
OK
MiNi-SMMS
OK
SMMS
OK
SHRM
OK
SMMS-i
OK
SHRM-i
OK
Timer terminal
Wired
remote
controller
Connecting wire
(accessory)
: Connector
Indoor
Outdoor
unit
unit
Basic diagram
64 system central remote controller or
ON-OFF controller
Wiring
specifications (1)
P1
U3 U4
U1 U2
Schedule timer *1
L3
P1
controller
Schedule
timer *2
Wiring specifications (2)
When installing multiple schedule timers, avoid the
use of communication line.
Connection diagram (Be sure to use the provided
wires as the power wiring.)
Wiring specifications (1)
If a 64 system central remote controller (or ON-OFF
controller) is installed (power is supplied from the 64
system central remote controller):
Inter-unit control wiring
U1
U2
64 system central remote controller
(Back side)
Wiring procedures
Connect the provided connecting wire to the power
terminal (4P connector) of the schedule timer.
The terminal attached to the clamp filter must be
connected to the schedule timer.
Wiring specifications (2)
If a 64 system central remote controller (or ON-OFF
controller) is not installed (power is supplied from the
indoor unit):
Indoor unit control PCB
CN61(T10)
1. Supplied parts
U3
U4
U1
U2
Indoor/Outdoor units communication line
(for S-MMS)
Central control system wiring
(for SDI/DI)
The length of the power wiring must be no more
than 100 m.
– 21 –
Refrigerant system 1
(S-MMS)
Refrigerant system 2
(SDI/DI)
Indoor unit
(Header unit)
Outdoor unit
U1 U2
U3 U4
L1
TCC-LINK
adapter
L
2
U3 U4
P1
U2
U1 U2
U1
Indoor
Indoor
Indoor
unit
unit
unit
Remote
Remote
Remote
controller
controller
Schedule
timer *3
Wiring specifications (2)
Connecting wire (accessory)
Field supply
Blue
Blue
Pink
Wire joint
(Not used)
Power terminal
(4P connector)
Communication
terminal (3P connector)
Schedule timer
(for SDI/DI)
(for S-MMS)
Black White
Blue
Blue
Pink
Wire joint
Power terminal
(Not used)
(4P connector)
Communication
terminal (3P connector)
Schedule timer
Refrigerant system 3
(S-MMS)
Outdoor unit
(Header unit)
U1 U2
U3 U4
L
4
U1 U2
Indoor
unit
Remote
controller
Clamp filter
Communication
wiring
(blue + pink)
Field supply
Communication
wiring
(blue + pink)
Power wiring
(black + white)