Appendix D. Foundation Fieldbus Communication
D.2.3 Connection
Connect the Fieldbus wires to P1 on the terminal PCB (see Figure 20 below). GE recommends using the top right rear
port on the enclosure.
IMPORTANT: Please make sure to follow all local installation guidelines.
D.2.4 FISCO (Fieldbus Intrinsically Safe Concept)
The XMT1000 Fieldbus is certified as a FISCO connection for both entity and FISCO parameters:
•
FISCO Parameters
V
or U
= 17.5 V
max
i
I
or L
= 380 mA
max
i
C
= 0
i
= 10 μH
L
i
P
= 5.32 W
i
•
Entity Parameters
V
or U
= 24 V
max
i
I
or L
= 250 mA
max
i
C
= 0
i
= 10 μH
L
i
P
= 5.32 W
i
58
Figure 20: FF Connection to XMT1000
P1
PanaFlow™ XMT1000 User's Manual