FIGURE 4 Configure Status page
3. In the Configure DS Frequency text box, enter the
downstream frequency (in Hertz) that you want the
cable modem to use to connect to the CMTS when it
boots up.
4. Click Set Values and Reboot to have the cable
modem save your changes and reboot.
Rebooting and Resetting the AP and CM
CAUTION!
Performing this procedure resets the AP
and CM parts of the T811-CM to their factory default
settings. If you want to reset only the CM component
to its factory default settings, then perform the
procedure described in Rebooting and Factory-
Resetting the CM instead.
NOTE: Resetting the AP and CM to factory default
settings erases all the settings that you have previously
configured. Also note that resetting and/or rebooting
the AP and CM disrupts all wireless network
communications through this device.
There are different ways to reboot or reset the AP and
CM parts of the T811-CM:
• Using the Reset Button Inside the AP
• Remotely Rebooting and Factory Resetting the AP
Using the Reset Button Inside the AP
You can reset the AP and CM to their factory default
settings by pressing the reset button behind the access
plug covering the Ethernet port.
1. Make sure that the AP is powered on.
2. Use a large flat blade screwdriver to remove the
screw-in access plug covering the reset button and
Ethernet port.
3. Locate the reset button under the access plug.
Copyright
©
2018 ARRIS Enterprises LLC. All rights reserved.
Published October 2018, Part Number 800-71744-001 Rev C
FIGURE 5 Location of the reset button
4. Using a pen or a similar pointed object, press the
reset button for 1-4 seconds to reboot the AP and
CM. Press and hold the reset button for 5-9 seconds
to reset the AP and CM to factory defaults.
5. Replace the access plug, and tighten to a torque of 7
in-lbs (0.7909 Nm).
You have completed resetting the AP and CM to their
factory default settings and/or rebooting the AP and CM.
Remotely Rebooting and Factory
Resetting the AP
You can also reboot and/or factory reset the AP using
SNMP.
NOTE: Before starting this procedure, you must first
obtain the related MIBs from Ruckus Wireless. Contact
your authorized Ruckus Wireless sales representative
or Ruckus Wireless Support. Visit https://
support.ruckuswireless.com/contacts for Ruckus Wireless
Support contact information.
1. Connect the administrative computer to the same
network as the T811-CM.
2. Start your MIB browser.
3. Load the Ruckus Wireless MIBs onto the MIB browser.
4. In the MIB browser, specify the IP address of the
T811-CM AP. (You can obtain this information from
the DHCP server on the network.)
5. Find the OID for the T811-CM reset and reboot
controls. Refer to the Ruckus Wireless Access Point
SNMP Reference Guide, available from
support.ruckuswireless.com, for AP-specific SNMP
MIBs.
• ruckusT811CMControlLED OID is: .
1.3.6.1.4.1.25053.3.1.4.97.3
6. Then do the following:
• To soft reset the AP, set the value to 10
(softResetAP).
• To factory-reset the AP, set the value to 12
(factoryResetAP).
You have completed remotely rebooting or factory-
resetting the access point using SNMP.
Installing the Safety Cable
1. Undo one of the strand mount bracket 1/4 20 nuts
and thread the security cable through the mounting
bracket and through the eye on the cable itself, as
shown in the following illustration.
2. Attach the other end of the safety cable to the strand
cable or other fixed anchor.
3. Reinstall the nut and torque to 85 in-lbs.
FIGURE 6 Attach the safety cable to the strand mount
bracket