Using the Recall Safe function
These buttons correspond to the following parameters.
Button name
ALL
All parameters (except for WITH MIX SEND)
EQ
EQ settings (including ATT)
DYNA 1
Dynamics 1 settings
MTRX ON
On/off status of signals sent to MATRIX buses
MTRX SEND
Send levels of signals sent to MATRIX buses
FADER
Fader positions
CH ON
On/off status of [ON] keys
WITH MIX
On/off status and send level of signals sent
SEND
from input channels to MIX buses
NOTE
• If the ALL button is on, all buttons will be turned off except for
the WITH MIX SEND button located in the lower part of the
SAFE PARAMETER field.
• You can switch the WITH MIX SEND button on/off while the
ALL button is left on.
●
If a MATRIX channel is selected
With the exception of the types of button that are dis-
played, this is the same as for a MIX channel.
In addition, you can use the WITH MATRIX SEND
button to enable Recall Safe for the on/off status and
send level of the signals sent from output channels to
MATRIX buses.
These buttons correspond to the following parameters.
Button name
All parameters (except for WITH MATRIX
ALL
SEND)
EQ
EQ settings (including ATT)
DYNA 1
Dynamics 1 settings
FADER
Fader positions
CH ON
On/off status of [ON] keys
On/off status and send level of signals sent
WITH MATRIX
from MIX channels / STEREO/MONO chan-
SEND
nels to MATRIX buses
NOTE
• If you turn on the ALL button, all buttons will be turned off
except for the WITH MATRIX SEND button located in the
SAFE PARAMETER field.
• You can switch the WITH MATRIX SEND button on/off while
the ALL button is left on.
142
LS9-16/32 Owner's Manual
Corresponding parameters
Corresponding parameters
4
To enable Recall Safe for the selected chan-
nel, turn on the SAFE button in the SAFE
PARAMETER field.
Channels for which Recall Safe is enabled will be
highlighted in the CH RECALL SAFE field.
NOTE
• Simply selecting a parameter in step 3 does not enable Recall
Safe. To turn Recall Safe on/off, you must also perform the
operation of step 4.
HINT
• In the CH RECALL SAFE field, the color of the highlight will
be green if the ALL button was selected in step 3, or blue if
buttons other than ALL were selected.
• If you press the CLEAR ALL button, Recall Safe will be
defeated for all channels for which it is enabled (i.e., the high-
lighted channels).
• You can also switch Recall Safe on/off in the SELECTED CH
VIEW screen's SAFE field ( → p. 88).
SAFE button
LS9-16
SAFE button
LS9-32