PCB Installation and Startup

Section 2: PCB Installation and Startup

PCB LAYOUT

PCB Location

Determine the slot position for each PCB. In the cabinet:
Slots 3 - 8 are universal (any type of PCB can be installed). The only restriction is that an ESIU PCB
can not be placed into slots 7 or 8 as there are not enough conversation channels.
Make sure to follow the steps indicated in Powering Up the System (page 2-40) for an initial
system install. This will ensure that you start the system with the default system settings.
To delete a PCB from the system, power down the system and then remove the PCB from the sys-
tem cabinet. Power the system back up and use Program 90-05-01 to delete the slot definition.
Whenever powering down the system, check to make sure the only LED flashing on the CPU
card itself (in the lower left-hand corner) is the LD2 LED (the LED located farthest right in the
line of LEDs). This LED is located in the lower left-hand corner of the CPU. It should be flash-
ing 0.5 seconds on/off (a slow flash). If it's flashing fast or if any other LEDS are flashing on the
CPU, wait until they stop or else the system data may be corrupted.
After turning the power on, the user must wait approximately 10 seconds (so that only the LD2
LED is flashing) if the system must be powered down again.