Download Print this page

Hitachi Hidic EH-150 Applications Manual page 63

Ethernet module
Hide thumbs Also See for Hidic EH-150:

Advertisement

Preliminary Rev.03
FUN 201 parameters for reading Status Register (SR)
I/O
WM0 Result (Error code)
WM1 System area
WM2
WM3 Control type (Read / write / etc)
WM4 EH-ETH slot number, and starting address for SR
WM5 Address of control bit for reading SR
WM6 Address of data for SR (Destination to read)
WM7 Data size for reading SR
R100 Execution bit for reading SR
R101 OK flag for reading SR
R102 Error flag for reading SR
Status register (SR) destination I/O
I/O
WM10 Data to read from MDSR
WM11 Data to read from C1ESR
WM12 Data to read from C2ESR
WM13 Data to read from C3ESR
WM14 Data to read from C4ESR
WM15 Data to read from C5ESR
WM16 Data to read from C6ESR
WM17 Data to read from C1CSR
WM18 Data to read from C2CSR
WM19 Data to read from C3CSR
WM1A Data to read from C4CSR
WM1B Data to read from C5CSR
WM1C Data to read from C6CSR
Setting for ASR connection
Cn. No. Usage
Protocol
Cn.1
Send
TCP/IP
Cn.2
Cn.3
Cn.4
Cn.5
Cn.6
(*1): This can be set as Active or Passive.
- Description in this manual might be modified without notice.
Description
Description
Open
Port No.
IP
Type
(*1)
*
4101
192.168.0.11
4102
4103
4104
4105
4106
Chapter 7 Automatic data transmission
FUN 201 parameters for writing Control Register
I/O
WM8 Result (Error code)
WM9 System area
WMA
WMB Control type (Read / write / etc)
WMC EH-ETH slot number, and starting address for CR
WMD Address of control bit for writing CR
WME Address of data for CR (Destination to read)
WMF Data size for writing CR
R103 Execution bit for writing CR
R104 OK flag for writing CR
R105 Error flag for writing CR
Control register (CR) source I/O
I/O
WM20 Data to write to MDCR
WM21 Data to write to CNCR
WM22 Data to write to EXSR
WM23 Data to write to RECR
WM24 Data to write to EXRR
WM25 Data to write to RDCR
WM26 Data to write to EC1CR
WM27 Data to write to EC2CR
WM28 Data to write to EC3CR
WM29 Data to write to CMCR
IP address: 192.168.0.10
Send
Port No.
Information
4111
Cyclic
4112
4113
4114
4115
4116
7-16
Description
Description
Cyclic
Send
Size (W)
time (s)
area Info.
2
WR000
80
WR050
WR0A0
WR100
WR150
WR1A0

Advertisement

loading

This manual is also suitable for: