Troubleshooting - Samsung AE RXYDEG Series Installation Manual

Air to water heat pump mono outdoor unit
Table of Contents

Advertisement

Troubleshooting

FAULT
No water flow from hot taps.
Water from hot taps is cold.
Intermittent water discharge
Continuous water discharge
Room thermostat does not switch
on or not work properly
Disconnect electrical supply before removing any electrical equipment covers.
NOTE
48
POSSIBLE CAUSE
1. Mains supply off.
2. Strainer blocked.
3. Cold water inlet Pressure Reducing
Valve incorrectly fitted.
1. Immersion heaters not switched on.
2. Immersion heater thermal cut-out has
operated.
3. Programmer set to central heating or
not switched on.
4. Boiler not working
5. Motorised valve not operating correctly.
1. Reduced internal expansion.
2. Thermal control failure. (Note Water will
be hot).
1. Cold water inlet Pressure Reducing
Valve not working
2. Temperature and pressure relief valve
faulty.
3. Expansion relief valve not working
correctly.
Wireless room thermostat batteries not
Working
REMEDY
1. Check and open stopcock.
2. Turn off water supply. Remove strainer and
clean.
3. Check and refit as required.
1. Check and switch on.
2. Check and reset button.
3. Check and set to hot water.
4. Check boiler operation. If fault suspected,
consult installer or boiler manufacturer.
5. Check wiring and/or plumbing connections to
motorized valve.
1. Repressurize expansion vessel. Follow cold
water discharge.
2. Switch off power to immersion heater(s) and
boiler supply to the unit. When discharge has
stopped, check thermal controls, replace it
faulty. Contact a competent person.
1. Check pressure from valve if greater than 2.1
bar replace.
2. As No2 of above.
3. Check and replace if faulty.
Replace new batteries for wireless room
thermostat